37 - DIAGNOSTICS
Memory data view
The control unit display allows you to view the values saved by
the system during operation and programming, such as: firmware
version loaded, number of manoeuvres performed, etc.
To view the value desired, proceed as follows:
1. press the +/- keys on the display until the "
then press ENT: the display will show the code
2. press the +/- keys to scroll through the codes (
the one desired then press ENT: the table below explains the
meanings of each of the codes;
3. the display will show the value of the parameter consulted
for 20 seconds using a variable display type depending on the
length of the value;
4. press ESC or wait to 20 seconds to return to the previous
menu, at this point you can consult another parameter by
following the same sequence or exit from the consultation by
pressing ESC again;
PARAMETRO DESCRIPTION
0
firmware version of the user controller
1
firmware version of the safety controller
2
type of automated system saved:
3
total weight of mass in movement:
P0
(0-100kg);
4
total number of manoeuvres performed by the
control unit
5
configuration of the sensors installed: refer
to the table of
describing the
m
DANGER: the total weight of the mass in movement
refers to the weight of a single leaf for single leaf
installations and the combined weight of the two leaves for
double leaf installations
m
DANGER: check that the indications of the parameters
stored in the control unit comply with the actual
characteristics of the system, with particular reference to
the weight of the leaves saves, the type of automated
system and the configuration of the sensors present. If
necessary, correct the values before activating the system.
Regular operation
The control unit display gives information on the operating status
of the system to make it easier to identify errors or malfunctions.
During normal operation the display shows the following
information
SIGNAL
DESCRIPTION
OP
Steady
Door open
OP
Flashing
Door opening
CL
Steady
Door closed
CL
Flashing
Door closing
St
Steady
Door stopped after obstruction or
intervention of safety sensors
All manuals and user guides at all-guides.com
In
" code appears
0
;
0
1
2
,
,
, ...) to
C0
C1
,
, ...
P1
P2
(100-200kg);
(200-300kg)
S
codes in the paragraph
LS
procedure
Errors on inputs of active safety devices
Before each opening/closing manoeuvre, the control unit checks
the active safety devices (sensors) via the test circuit and if a fault
is detected does not carry out the manoeuvre. In this case, the
display will show an F code error (ref. table below) which refers
to the pending test (awaiting completion) of one of the safety
devices installed:
SIGNAL
DESCRIPTION
F1
Flashing
Supervision of Safe Close 1 failed
F2
Flashing
Supervision of Safe Close 2 failed
F3
Flashing
Supervision of Safe Open 1 failed
F4
Flashing
Supervision of Safe Open 2 failed
The signal code indicates that the test on the safety device cannot
be completed: this situation arises due to a fault with the sensor
or if there is something activating the sensor (e.g. person or
object in the field of action). Find the cause of the problem, first
checking that the sensor's field of action is clear of persons or
objects and that the wiring is intact and connected correctly.
Protection circuit errors
SIGNAL
DESCRIPTION
F8
Flashing
Communication error with Safety
Controller, active warning only when the
door is stationary
F9
Flashing
Test error output safety function
F8
F9
Errors
and
, if are not resolved automatically after a brief
period, indicates a possible internal fault with the control unit in
the communication system between the two microprocessors or in
the system installed for the emergency cut-off of the motor. If the
problem persists, replace the control unit.
- 39 -