Télécharger Imprimer la page

V2 SLAID140 Manuel D'instructions page 35

Publicité

Les langues disponibles

Les langues disponibles

32 - TERMINAL BOARD CONNECTIONS (FROM Fig.68 TO 73)
Connect all the components of the automatic door to the control unit with the appropriately sectioned electrical cables, in compliance with
the instructions in the following table:
N
REFERENCE
1
START1
2
COM
3
OPTOREF
4
-OO-
5
START2
6
OUT 15VDC
7
OUT 15VDC
8
TEST CLOSE
9
TEST CLOSE
10
COM
11
PHOTO COM
12
SAFE CLOSE 1
13
SAFE CLOSE 2
14
TEST OPEN
15
TEST OPEN
16
COM
17
SAFE OPEN 1
18
SAFE OPEN 2
19
OUT 15VDC
20
OUT 15VDC
21
OUT 15VDC
22
OUT 15VDC
COM
23
KEY
24
AUX OUT
25
AUX IN 1
26
AUX IN 2
27
LOCK
28
LOCK
29
-
30
GND
31
DATA
32
PWF
33
RST
34
AUX SEL
m
DANGER: comply with the connections in the table, comply with the polarities where necessary, do not connect the
utilities with absorptions over the limits in the table. The unit already has a series of bridged terminals (indicated in the table).
If these inputs are used for connection of the sensors, you need to remove the bridges.
On the contrary, an important safety function and movement of the doors could be compromised and could cause serious
damage to property and people with the risk of fatal injuries
All manuals and user guides at all-guides.com
DEFAULT
DESCRIPTION
NO
External sensor for opening command
Common for inputs 1-5
Not used (bridged)
Not used (bridged)
NO
Internal sensor for opening command
(-)
Negative power supply for opening command sensors:
15Vdc - max. 0.25A
(+)
Positive power supply for opening command sensors:
15Vdc - max. 0.25A
(-)
Negative test circuit of the opening command sensor
(+)
Positive test circuit of the opening command sensor
Common signal for inputs 12-13
Not used
NC
Active external presence sensor (zone A2)
NC
Active external presence sensor (zone A1)
(-)
Negative test circuit of side opening safety sensors
(+)
Positive test circuit of side opening safety sensors
Common signal for inputs 17-18 (bridged)
NC
Right side opening safety sensor - zone A3 (bridged)
NC
Left side opening safety sensor - zone A4 (bridged)
(-)
Positive power supply on safety sensors in side opening:
15Vdc - max. 0.25A
(+)
Negative power supply on safety sensors in side opening:
15Vdc - max. 0.25A
(-)
Negative peripheral power supply:
15Vdc - max. 0.25A
(+)
Positive peripheral power supply:
15Vdc - max. 0.25A; additional common signal
NC
Night closure command
Auxiliary output
Auxiliary input
Auxiliary input
(+)
Electric lock
L
Electric lock
(-)
Not used
Logical selector GND cable
Logical selector DATA cable
Logical selector PWF cable
Logical selector RST cable
Auxiliary output
- 33 -
FIGURE
Fig.68
Fig.69
Fig.70
Fig.71
-
-
-
Fig.72
-
Fig.73
-

Publicité

loading

Ce manuel est également adapté pour:

Slaid160