F
7. the flashing
... code indicates that the
because one or more of the inputs of the safety devices are
active instead of at rest; use the table below to identify the
inputs from the code on the display:
Safe
Signal
Open 2
F1
Flashing
At rest
F2
Flashing
At rest
F3
Flashing
At rest
F4
Flashing
At rest
F5
Flashing
At rest
F6
Flashing
At rest
F7
Flashing
At rest
F8
Flashing
Active
F9
Flashing
Active
FA
Flashing
Active
Fb
Flashing
Active
FC
Flashing
Active
Fd
Flashing
Active
FE
Flashing
Active
FF
Flashing
Active
Note the error code, press ESC to exit the
look for the cause of the error on the individual input from the
following possible errors:
• setting error in the polarity of the supervised inputs/outputs
• setting error logic values NO/NC of the inputs or outputs of the
safety circuit of the sensors
• presence of persons or objects in the detection field of one of
the safety sensors
• hardware malfunction of one of the components
Eliminate the causes of the error and repeat the
from point 1.
NOTE: it is possible to exit the
the ESC key.
m
LS
DANGER: once the
modifications must not be made to the system or the
connection or configuration of the sensors.
LS
If modified, the
procedure must be repeated.
If not, the safety devices could fail to work and the
automatic movement of the doors could cause serious
injury or damage to persons or objects with the risk of fatal
lesions.
All manuals and user guides at all-guides.com
LS
cannot terminate
Safe
Safe
Safe
Open 1
Close 2
Close 1
At rest
At rest
Active
At rest
Active
At rest
At rest
Active
Active
Active
At rest
At rest
Active
At rest
Active
Active
Active
At rest
Active
Active
Active
At rest
At rest
At rest
At rest
At rest
Active
At rest
Active
At rest
At rest
Active
Active
Active
At rest
At rest
Active
At rest
Active
Active
Active
At rest
Active
Active
Active
LS
procedure and
LS
procedure
LS
at any time by pressing
procedure is complete,
35 - LEARN PARAMETERS (
PROCEDURE
LP
The learn parameters (
acquire essential operation data such as the dimensions of the
doorway opening, the weight of the leaves and the direction of
opening.
WARNING: before carrying out the LP, you must ensure that
there are no obstructions of excessive friction resisting the
sliding of the leaves. Carefully check all internal mechanical
parts of the automated system that interact with the sliding
mechanism (wheels, carriages, anti-derailing device, belt,
etc.) and all fastenings of moving and fixed parts with
particular reference to the floor guide rails and air seals
or brushes that can resist the sliding action of the leaves.
Faults may lead to malfunction of the product or excessive
wear of some parts.
m
ATTENTION: Always position the door/s in closure,
before starting the procedure.
LP
Activate the
procedure as shown below using the keys and
display:
1. press the +/- keys on the display until the
then press ENT: the display will show the code
2. press and hold the ENT key (around 5 seconds) until the
segments of the display begin to rotate; when the
appears the control unit waits 10 seconds for the leaves to be
fully closed by hand;
m
ATTENTION: Move from the sensors field because,
having the safety devices active, if you are detected the
procedure will not conclude and the display will indicate
St
.
3. the procedure activates and the automated system carries
out a number of openings and closings (max 5) in order to
measure the parameters; if completed correctly, at the end of
the procedure the leaves will be fully closed: if when in the
final stop position the leaves are not fully closed, repeat the
from point 1.
- 36 -
LP
)
) procedure allows the control unit to
LP
code appears
--
;
St
code
LP