34 - LEARN SENSOR PROCEDURE (
LS
The learn sensor procedure (
automatically detect the sensors connected with particular
reference to the presence and quantity of supervised sensors.
After detection, the control unit shows on the display the
configuration and type of sensors it has detected: it is the
responsibility of the installation technician to verify that the
configuration shown on the display corresponds with the actual
installation and then definitively confirm the configuration if it is
correct for the purpose. From that moment, the control unit with
use the configuration confirmed.
m
DANGER: before confirming the acquisition, carefully
check that the configuration detected by the control unit is
suitable for the system and check that all the safety devices
are detected correctly. If not, the safety devices could fail
to work and the automatic movement of the doors could
cause serious injury or damage to persons or objects with
the risk of fatal lesions.
m
DANGER: to carry out the LS procedure correctly, all
the sensor and control unit inputs must have correct NO
and NC values. Check the default values of the control unit
inputs in the table and those of the inputs of the sensor
in the manual of the sensor. If they are incompatible,
reprogram the specific input in the control unit by following
the procedure described in this manual. If not, the safety
devices could fail to work and the automatic movement of
the doors could cause serious injury or damage to persons
or objects with the risk of fatal lesions.
LS
Activate the (
) procedure as described below using the keys
and display:
1. press the +/- keys on the display until the
then press ENT: the display will show the code
2. press and hold the ENT key for 5 seconds until the counter
appears counting from 30 down to 0: the procedure has
started correctly;
3. you have 30 seconds to: close the cover of the automated
system, check that the sensors are in the correct position,
clear the detection area removing any obstacles in front of the
sensors;
m
ATTENTION: Approximately 30 seconds are available
to close the automatism cover, check the sensors are in the
correct position and free the detection areas by removing
any obstacles under the sensors; after 30 sec. the unit resets
the sensors and acquires their configuration in approx.
LS
10 sec; the
procedure lasts 40 sec. overall; you will
recognise the end of the procedure when the sensors stay
in standby.
4. after 30 seconds, the control unit resets the sensors and
acquires the configuration in 10 seconds; the
lasts 40 seconds in total; you can see the
finished when the sensors go into stand-by mode;
5. after 40 seconds, open the cover of the automated system and
read the code on the display: if the code begins with
the instructions in point 6; if the code begins with
instructions in point 7.
S
6. the code
indicates which sensors have been detected
according to the correspondence of the table below; check
that the information on the display corresponds to the sensors
actually installed and if so press ENT to confirm and save the
configuration (the display will show
LP
for
procedure); if not press ESC, check the wiring of the
LS
sensors and repeat the
All manuals and user guides at all-guides.com
LS
) allows the control unit to
LS
code appears
--
;
LS
procedure
LS
procedure has
S
follow
F
follow the
E1
flashing - waiting
from point 1.;
)
Signal
S0
S1
S2
S3
S4
S5
S6
S7
S8
S9
SA
Sb
SC
Sd
SE
SF
NOTE: YES/NO indicates whether an active safety device
with the test function in accordance with EN16005 has been
detected in the input.
- 35 -
Safe
Safe
Safe
Open 2
Open 1
Close 2
NO
NO
NO
NO
NO
NO
NO
NO
YES
NO
NO
YES
NO
YES
NO
NO
YES
NO
NO
YES
YES
NO
YES
YES
YES
NO
NO
YES
NO
NO
YES
NO
YES
YES
NO
YES
YES
YES
NO
YES
YES
NO
YES
YES
YES
YES
YES
YES
Safe
Close 1
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES