36 - PARAMETERS SETTING MODE
LS
After completing the
and
ready to operate with the default parameters or with the latest
parameters set by the installation technician. It is possible to
change the settings using the keys of the control unit and relative
display.
To change the adjustments of the table below, proceed as follows:
1. press the +/- keys to show the number of the parameter to be
01
modified:
opening speed,
2. press ENT: the value of the parameter present is shown;
ID
DESCRIPTION
01
Opening speed
02
Closing speed
03
Pause time
04
Opening anti-crushing
05
Closing anti-crushing
06
Partial opening percentage
07
Approach speed
08
Accelerations
09
Decelerations
10
Approach
11
Opening limit
12
Door closed hold force
13
Type of electric lock
14
Door lock logics with electric lock
or motor
15
Auxiliary 1 input configuration
(defining NO / NC type of
parameter 26)
16
Auxiliary 2 input configuration
(defining NO / NC type of
parameter 27)
17
Auxiliary output configuration
(defining NO / NC type of
parameter 29)
All manuals and user guides at all-guides.com
LP
procedures, the control unit is
02
closing speed, etc.;
ADJUSTMENT
20cm/s ÷ 70cm/s adjustment step 5cm/s.
10cm/s ÷ 40cm/s, adjustment step 5cm/s.
0 - 60
seconds, adjustment step 1 second
1 – 9
(1 minimum, 9 maximum)
1 – 9
(1 minimum, 9 maximum)
30 - 90
percentage of opening in relation to total
3cm/s ÷ 10cm/s adjustment step 1cm/s.
5 - 30
adjustment step 1
5 - 20
adjustment step 1
10cm - 40cm adjustment step 1cm modification of both values (opening equal
to 1/2 of closing)
0% - 50% adjustment step 1%. Movement limit in relation to travel of the leaf
0 - 9
adjustment step 1, 0 disabled, 9 maximum
0
Not used
1
Normal
2
Inverted
3
Bistable
4
Safety bistable with motor door lock only is KEY active
0
Lock deactivated
1
Lock active in One Radar
2
Lock active in Two Radar
3
Lock active in One Radar and Two Radar
If no electric lock is selected the door is locked by the motor
0
Emergency open
1
Interlock Master
2
Interlock Slave
3
Opening pharmacy mode
4
Repeat command Start 2
5
Semiautomatic
6
Stop motion
7
Partial opening command
0
Emergency open
1
Interlock Master
2
Interlock Slave
3
Opening pharmacy mode
4
Repeat command Start 2
5
Semiautomatic
6
Stop motion
7
Partial opening command
0
Not used
1
Interlock
2
Status door Open
3
Status door Close
4
Fault
5
Bell
3. select the desired value with the +/- keys then press ENT to
confirm the value selected: the value is saved by the control
unit;
4. press ESC to end the procedure
NOTE: if the keys are not pressed for 10 seconds during the
adjustment, the control unit exits the procedure and returns to
normal operation mode.
The table below shows the parameters and relative display code:
- 37 -
DEFAULT
60
20
0
9
7
50
5
24
16
20
0
0
1
1
1
0
0