Technical data

Supply voltage/frequency
Supply power/rated current
Connection cable length
Insulation material class
Degree of protection
Operating mode
Alarm contact
Permissible medium temperature
Permissible medium
Maximum conveying height
Maximum conveying quantity
Sound pressure level
Tank volume
Weight
Condensate pump width
Condensate pump height
Condensate pump depth
Condensate supply height
Condensate supply
Condensate drain with check valve
Switching points
EN
KP 51
KP 150
230 V AC / 50 Hz
230 V AC / 50 Hz
70 W / 0.67 A
150 W / 1 A
Mains cable:
2 m
Mains cable:
Alarm cable:
2 m
Alarm cable:
B
B
IP 20
IP 20
S3 30% – intermittent operation:
S3 80% – intermittent operation:
3s ON – 7s OFF
8min ON – 2min OFF
Normally closed contact 4 A resis-
230V / 3A
tive load – 250 V (NC)
COM = 1, NC = 2, NO = 3
Max. 50 °C
Max. 50 °C
Condensate water, pH >2.5
Condensate water, pH >3.5
5.4 m
6.0 m
500 l/h
340 l/h
45 dBA at a distance of 1 m
45 dBA at a distance of 1 m
2.0 l
4.0 l
1.85 kg
3.6 kg
279 mm
305 mm
171 mm
267 mm
130 mm
153 mm
85 mm
145 mm
Ø 30 mm
Ø 28.5 mm
Ø 10 mm
Ø 10 mm
ON:
53 mm
OFF:
42 mm
ALARM:
64 mm
KP 250
230 V AC / 50 Hz
150 W / 1 A
2 m
Mains cable:
2 m
Alarm cable:
B
IP 20
S3 80% – intermittent operation:
8min ON – 2min OFF
230V / 3A
COM = 1, NC = 2, NO = 3
Max. 50 °C
Condensate water, pH >3.5
6.0 m
800 l/h
45 dBA at a distance of 1 m
4.0 l
3.6 kg
305 mm
267 mm
153 mm
145 mm
Ø 28.5 mm
Ø 10 mm – no check valve
KP 350
230 V AC / 50 Hz
70 W / 0.67 A
2 m
Mains cable:
2 m
Alarm cable:
B
IP 20
S3 100%
Normally closed contact 4 A resistive load
– 250 V (NC)
Max. 87 °C
Condensate water, pH >3.4
10.0 m
1100 l/h
66 dBA at a distance of 1 m
3.8 l
5.9 kg
305 mm
257 mm
152 mm
130 mm
Ø 32mm / 15 mm
Ø 12 mm
ON:
OFF:
ALARM:
Notes
2 m
1 m
81 mm
48 mm
101 mm
13

Publicité