EN
Gate stopped during opening (power loss, button used,
emote control used, or the barrier breached)
„OH"
Gate stopped during opening by static overload protection
"OH."
Gate stopped during opening by dynamic overload protection
"O.H"
Remote control used while active HOLD TO RUN function
Message "
Au
" appearing and disappearing every few seconds
the gate is performing automatic overload configuration procedure
The lack of response to remote control
or button when the barrier is breached.
The lack of response to remote control when the Settlement function
is active and other user took over control of the gate.
Automatic function of dynamic and static secure selection is active
The gate stopped due to short circuit the motor.
8
Assembly and Operating Instructions - ST-2 sliding gate steering unit
„oH"
"oH."
"o.H"
"
H r
"
The gate stopped due to lack of active GND on STOP2 input
The gate stopped due to change on STOP1 input
(value greater than16,2K or less than 2K ).
Gate stopped by static overload protection
Gate stopped by dynamic overload protection
Gate stopped due to hitting an obstacle during starting to move
The display turned off - dots on the display blink alternately.
VIII. INSTALLATION AND FIRST RUN
P
Disconnect the power supply.
P
Fix the steering unit in intended place in the gate column.
P
Screw on extension board so that the connector screws are placed on the
bottom.
P
Connect to the connector screws necessary wires:
-
Power supply.
-
Light indicator (25 Watt max).
- O
pen/close detectors.
•
Active no GND - NC
(domyślne ustawienie).
•
Active GND - NO.
-
The barrier (NC) - optional.
-
Wired control buttons (NO) - optional.
-
STOP1 input to plug protection slatted - optional.
-
STOP2 input (NC) optional.
P
Connect the steering unit to the socket in the extension board.
P
Insert the 6.3 A F fuse to the socket in the extension board.
P
Turn on the power ( ~ 24V).
P
Use the included pilots to test the gate.
P
Set up open/close detector switches in such a way that the gate would
not hit ending columns during fast move.
P
Perform the automatic overload protection configuration procedure (Look
IIiO/ST-2/12/2013/ID-91384 Technical Documentation