9.2. Static protection ("St")
Static protection controls absolute maximum value of the current drawn by
the motor propelling the gate, at which the steering unit stops the gate. Static
overload protection is an additional protection (for example, if user turns off
dynamic protection by pressing and holding remote control button). This
value is set automatically by the steering unit (Look
è
programming mode
configuration
) or manually by the installer (Look
è
programming mode
Static overload protection
overload protection
).
WARNING! Static overload protection cannot be
disabled.
9.3. Automatic dynamic and static overload protection
configuration
Automatic dynamic and static protection configuration function is performed
by the steering unit by doing two complete opening and closing cycles
during which both protection parameters are automatically set. After
completing automatic protection configuration procedure (Look
Steering unit programming mode
protection configuration
) the gate should be run several times under
supervision of the installer. During configuration procedure the steering unit
sets both parameters to their maximum values, and word "
and disappear on the display several times.
VII. DISPLAYED MESSAGES
During the opening or closing the gate on the display:
P
two characters flash when the gate moves with maximum speed,
P
last character flashes when the gate moves slowly.
Steering unit calibrated
Gate closed
„CL"
Gate closing (fast move)
Gate closing (slow move)
Gate stopped during closing (power loss, button used,
remote control used, or the barrier breached)
„CH"
P
Technical Documentation IIiO/ST-2/12/2013/ID-91384
Assembly and Operating Instructions - ST-2 sliding gate steering unit
è
Steering unit
Automatic overload protection
è
Steering unit
è
Dynamic
è
Automatic overload
PA
" may appear
Steering unit not calibrated
„cL"
„cH"
Make sure that during automatic configuration the gate not encounter any
obstacles on its way. After completion of the procedure the steering unit
saves the measured values of both protection parameters.
9.4. Procedure of stopping the gate after overload
After forced stop of the gate during closing or opening the steering unit stops the
gate and moves it back for a short distance to help to remove the obstacle. In
addition, the display will show appropriate message specifying the reason for
stopping the gate (Look
If the automatic gate closing function is active:
P
after forced stop during closing the gate will open and attempt to re-close
è
(Look
OPERATING THE GATE
P
after forced stop during opening the gate will close.
10. Lifetime counters
The steering unit has counters counting the number of particular events
occurred during the gate's lifetime. You can check how many times the gate
closed, opened, how many times the gate stopped during opening or
closing. Maximum value of every counter is 999999.
To check counter values look:
è
è
Steering unit programming mode
è
Steering unit programming mode
è
Steering unit programming mode
during closing.
è
Steering unit programming mode
during opening.
Gate stopped during closing by static overload protection
„CH."
Gate stopped during closing by dynamic overload protection
„C.H"
„OP"
è
DISPLAYED MESSAGES
).
è
AUTOMATIC GATE CLOSING
è
Number of closings.
è
Number of openings.
è
Number of stops
è
Number of stops
„cH."
„c.H"
Gate open
„oP"
Gate opening (fast move)
Gate opening (slow move)
EN
),