Télécharger Imprimer la page

Wisniowski ST-2 Notice De Montage Et De Fonctionnement page 11

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 38
P
Press "OK" to accept selection.
P
Number between 0.5 - 6.2 will appear on the display. The number
indicates the value of which could increase the current drawn (in
Amperes) by the motor propelling the gate in single step which will result
in an immediate gate stop.
P
Use (+), (-) buttons to select new value.
P
Press "OK" to save new setting or "CANCEL" to return.
P
To return to normal operation press "CANCEL" button as many times until
the one of the messages described in paragraph "DISPLAYED
MESSAGES" will appear on the display.
6. Automatic overload protection configuration
P
Enter steering unit programming mode (Look
è
programming mode
Entering the installer code
P
Select
"PA"
function using (+), (-) buttons.
P
Press "OK" to accept selection.
P
Message showing current working state ("on" - enabled, "of" - disabled)
will appear on the display.
P
Use (+), (-) buttons to select new value.
P
Press "OK" to save new setting or "CANCEL" to return.
P
To return to normal operation press "CANCEL" button as many times until
the one of the messages described in paragraph "DISPLAYED
MESSAGES" will appear on the display.
7. Resetting the steering unit calibration
P
Enter steering unit programming mode (Look
è
programming mode
Entering the installer code
P
Select
"Cr"
or
"cr"
function using (+), (-) buttons.
"Cr"-
the steering unit is calibrated (measured length of the gate and
slow move near ends) To reset calibration press "OK" button 5 times.
"cr"
- the steering unit is not calibrated.
P
To return to normal operation press "CANCEL" button as many times until
the one of the messages described in paragraph "DISPLAYED
MESSAGES" will appear on the display.
8. Pedestrian gate function
P
Enter steering unit programming mode (Look
è
programming mode
Entering the installer code
P
Select
"Fr"
function using (+), (-) buttons.
P
Press "OK" to accept selection.
P
Number between 1 and 15 or
"0"
"0" - function is disabled
P
Technical Documentation IIiO/ST-2/12/2013/ID-91384
Assembly and Operating Instructions - ST-2 sliding gate steering unit
è
Steering unit
).
è
Steering unit
).
è
Steering unit
).
or
"- -"
will appear on the screen:
. The button No. 2 on the remote control
does not work. The button No. 1 and both wired buttons cause full
opening or closing the gate.
"- -" - function is disabled
control are swapped. The button No. 1 does not work. The button No. 2
and both wired buttons cause full opening or closing the gate. This setting
can be helpful during 2 gates operation mode.
Number between 1-15 function is enabled
the width of the gate expressed in sixteenth parts of the full width of the
gate (for example 4 means 4 / 16 of the width of fully opened gate that
is about 25% of the gate width).
P
Use (+), (-) buttons to select new value.
P
Press "OK" to save new setting or "CANCEL" to return.
P
To return to normal operation press "CANCEL" button as many times until
the one of the messages described in paragraph "DISPLAYED
MESSAGES" will appear on the display.
9. Operating 2 gates
There is a possibility of an independent control of two gates located in close
proximity using the same set of remote controls.
To make it possible the following conditions must be met:
P
Remote controls must be programmed in both gate steering units (Look
Steering unit programming mode
è
programming or Look
è
Entering the installer code
Programming new remote controls
P
Set up an appropriate function in both steering units (Look
è
unit programming mode
Steering unit 1
Steering unit 2
Disable pedestrian gate
Disable pedestrian gate function and
function (setting
"0"
selected)
swap remote control buttons
(setting
After making the settings first button of remote controls will operate one gate
while second button will be responsible for the second gate.
10. Setting the lamp on time after closing/opening the gate
P
Enter steering unit programming mode (Look
è
programming mode
Entering the installer code
P
Select
"tL"
function using (+), (-) buttons.
P
Press "OK" to accept selection.
Number between 0.0 - 9.9 will appear on the display.
Value 0.0 indicates that the lamp will immediately fade after opening or
closing the gate.
Value between 0.1 - 9.9 indicates the lamp on time in minutes.
P
Use (+), (-) buttons to select new value.
P
Press "OK" to save new setting or "CANCEL" to return.
P
To return to normal operation press "CANCEL" button as many times until
the one of the messages described in paragraph "DISPLAYED
MESSAGES" will appear on the display.
11. Remote controls
The steering unit can support up to 60 remote controls. There are also other
versions of the steering unit available, which can support up to:
P
170
remote controls,
P
270
remote controls,
P
370
remote controls,
P
470
remote controls.
Every remote control has its own position in the steering unit's memory and
. Buttons No. 1 and No. 2 on the remote
. The value indicates
è
Easy remote controls
Steering unit programming mode
è
Remote controls
).
è
Steering
Pedestrian gate function
):
"- -"
selected)
è
Steering unit
).
EN
è
è
11

Publicité

loading

Produits Connexes pour Wisniowski ST-2