2.3
GENERAL INFORMATION
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
QUALITY!
Altitude (FT)
Max. Input (BTU/HR)
Max. Output Steady State (BTU/HR)
Effi ciency (w/the fan on)
Min. Inlet Gas Supply Pressure
Max. Inlet Gas Supply Pressure
Manifold Pressure (Under Flow Conditions)
When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specifi c recommendations
from the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of 4% for
each additional 1,000ft (305m).
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is certifi ed for mobile home
installation.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible
for use with other gases, unless a certifi ed kit is used.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected.
NOTE: The protective wrap on plated parts is best removed when the assembly is at room temperature but this
can be improved if the assembly is warmed, using a hair dryer or similar heat source.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the
appliance and shall be installed.
RATES AND EFFICIENCIES
NG
0-4,500
24,000
17,280
72%
4.5" WC (11mb)
7" WC (17mb)
3.5" WC (9mb)
7
LP
0-4500
24,000
17,280
72%
11" WC (27mb)
13" WC (32mb)
10" WC (25mb)
W415-1335 / 06.27.14