General Information; Rates And Efficiencies - Napoleon WHD31P Manuel D'installation Et D'opération

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installer, please fill out the following information:
Customer:
Address:
Date of Installation:
Location of Appliance:
Installer:
Dealer/Distributor Contact Number:
Serial #:
Model:
Natural Gas:

1.0 general information

When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specific
recommendations from the local authority having jurisdiction, the certified high altitude input rating shall be
reduced at the rate of 4% for each additional 1,000ft (305m). Expansion / contraction noises during heating up
and cooling down cycles are normal and are to be expected.
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is suitable for mobile
home installation.
The natural gas model can only be installed in a mobile home that is
permanently positioned on its site and fueled with natural gas. This
appliance may be installed in an aftermarket permanently located,
manufactured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other
gases, unless a certified kit is used.
note:
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance and must
be installed.
The protective wrap on plated parts is best removed when the assembly is at room temperature but this can be
improved if the assembly is warmed using a hair dryer or similar heat source.
This appliance is a decorative product. It is not a source of heat and not intended to burn solid fuel.
1.1

rates and efficiencies

For your satisfaction, this appliance has been fire-tested to assure its operation and quality!
Altitude
Maximum Input
Maximum Output
Efficiency
Minimum Inlet Gas Supply Pressure
Maximum Inlet Gas Supply Pressure
Manifold Pressure Under Flow Conditions
* Maximum inlet pressure not to exceed 13".
______________________________________________________________
______________________________________________________________
______________________________________________________________
______________________________________________________________
______________________________________________________________
______________________________________________________________
______________________________________________________________
WHD31N
RATES AND EFFICIENCIES
standard checklist
WHD31P
Propane:
ENGLISH:
65.2%
CWHD31
65.2%
WHD31
FRENCH:
Cote énergétique des foyers à gaz
Basée sur la norme CSA P.4.1-02
Modèle No.
NATURAL GAS
0 - 4,500
Cote énergétique des foyers à gaz
20,000 BTU/hr
13,780 BTU/hr
Basée sur la norme CSA P.4.1-02
Modèle No.
65.2%
4.5" (11mb) Water Column
7"* (17mb) Water Column
3.5" (9mb) Water Column
65.2%
WHD31
PROPANE GAS
0 - 4,500
65.2%
16,000 BTU/hr
11,136 BTU/hr
CWHD31
64.8%
11" (27mb) Water Column
13" (32mb) Water Column
10" (25mb) Water Column
W415-1337 / B / 09.25.18
EN
5

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Whd31nPlazmafire 31

Table des Matières