2.3
GENERAL INFORMATION
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION
AND QUALITY!
Altitude
Maximum Input
Maximum Output
Effi ciency
Minimum Inlet Gas Supply Pressure
Maximum Inlet Gas Supply Pressure
Manifold Pressure Under Flow Conditions
* When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specifi c
recommendations from the local authority having jurisdiction, the certifi ed high altitude input rating shall be
reduced at the rate of 4% for each additional 1,000ft (305m) .
Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible
for use with other gases, unless a certifi ed kit is used.
Provide adequate accessibility clearance for servicing and operating the appliance.
Never obstruct the front opening of the appliance.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance
and shall be installed.
2.4
RATING PLATE INFORMATION
DIRECT VENT VENTED GAS FIREPLACE APPROVED FOR BEDROOM, BATHROOM & BEDSITTING ROOM
INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE
CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED
STATES THE MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280.
WHEN THIS US STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR
MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A.
MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG)
PRESSION AU COLLECTEUR: 3.5" D'UNE
MIN SUPPLY PRESSURE: 4.5" W.C.(NG)
PRESSION D'ALIMENTATION MIN: 4.5" D'UNE
MAX. SUPPLY PRESSURE: 7" W.C. (NG)
PRESSION D'ALIMENTATION MAX: 7" D'UNE
FOR USE WITH GLASS DOORS CERTIFIED
WITH THIS UNIT ONLY. FOR USE ONLY WITH
BARRIER W565-0170. FOLLOW THE
INSTALLATION INSTRUCTIONS LOCATED IN
THE INSTALLATION MANUAL.
WARNING: DO NOT ADD ANY MATERIAL TO THE
APPLIANCE, WHICH WILL COME IN CONTACT
WITH THE FLAMES, OTHER THAN THAT SUPPLIED
BY THE MANUFACTURER WITH THE APPLIANCE.
THIS VENTED GAS FIREPLACE IS NOT FOR USE
WITH AIR FILTERS.
ELECTRICAL RATING: BLOWER KIT GS66, 115V
0.5AMP 60HZ THE APPLIANCE MUST BE VENTED
USING THE APPROPRIATE WOLF STEEL VENT KITS.
SEE OWNERS INSTALLATION MANUAL FOR VENTING
SPECIFICS. MINIMUM AND MAXIMUM VERTICAL
VENT LENGTHS ARE 3 FEET AND 35FEET
RESPECTIVELY.
* MAXIMUM HORIZONTAL EXTENSION 2". SEE INSTRUCTION MANUAL FOR GREATER EXTENSIONS.
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
RATING PLATE LOCATION: The rating label is located behind the control panel and is chained to the
appliance. DO NOT REMOVE.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
RATES AND EFFICIENCIES
CONFORMS TO / CONFORME AUX: ANSI Z21.50-2014, CERTIFIED TO / CERTIFIE CSA 2.22-2014 VENTED GAS FIREPLACE / FOYER À GAZ VENTILÉ.
9700539 (WSL)
4001658 (NAC)
COLONNE D'EAU(GN)
NATURAL GAS MODEL
CDV19N
GD19N
COLONNE D'EAU (GN)
0-4500ft
11,500 BTU/h
COLONNE D'EAU (GN)
8,000 BTU/h
NOT FOR USE WITH SOLID FUEL
55.9%
MINIMUM AND MAXIMUM HORIZONTAL VENT
LENGTHS ARE 8 INCHES AND 20 FEET
RESPECTIVELY. PROPER REINSTALLATION AND
RESEALING IS NECESSARY AFTER SERVICING
THE VENT-AIR INTAKE SYSTEM.
DECORATIVE PRODUCT: NOT FOR USE AS A HEATING
APPLIANCE
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL:
CE TO COMBUSTIBLE MATERIAL
TOP
0"
MANTEL
MANTEL
FLOOR
0"
RECESSED DEPTH 13"
RECESSED DEPTH 13"
SIDES
0"
VENT
VENT
BACK
0"
TOP, SIDES & BACK: PER STAND OFF SPACERS
P, SIDES & BACK: PER STAND O
FOR FRAMING MATERIALS. FOR FINISHING
OR FRAMING MATERIALS. FOR FIN
MATERIALS SEE OWNERS MANUAL.
MATERIALS SEE OWNERS MANUA
UAL FOR GRE
NATURAL GAS
0 - 4,500*
11,500
8,600
75%
4.5" (11mb) Water Column
7" (17mb) Water Column
3.5" (9mb) Water Column
FOYER À GAZ VENTILÉS À ÉVACUATION DIRECTE. HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER,
TION DIR
UNE SALLE DE BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI SON INSTALLATION
DIO. APPR
CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SERIE DE MAISONS MOBILES EQUIPEES AU GAZ, EN
NCES DE LA NORME
VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA NORME DE SECURITE ET DE CONSTRUCTION DE MAISONS
CANADA OU AUX ETATS
MANUFACTUREES, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT ETRE
EES, TITRE 24 CFR, SECTION 3280
APPLIQUEE, SE REFERER A LA NORME RELATIVE AU CRITERE DE MESURES DE SECURITE CONTRE L'INCENDIE POUR
ER A LA NORME RELATIVE AU CR
LES INSTALLATIONS DANS LES MAISONS MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 501A.
DANS LES MAISONS MANU
4001657 (NGZ)
016
4001659
4001659 (WUSA)
PROPANE MODEL
OPANE M
GD19P
GD19P
ALTITUDE / ELEVATION
EVATION
0-4500ft
0-4500ft
INPUT / ALIMENTATION
MENTATION
11,000
11,000 BTU/h
REDUCED INPUT /
CED INPU
ALIMENTATION REDUITE
ATION REDUITE
55.9%
P4
P4
UTILISER AVEC LES PORTES VITREES
LISER AVEC
T
HOMOLOGUEES SEULEMENT AVEC CETTE
HOMOLOGUEES S
UNITE OUR UN
UNITE. POUR UNE UTILISER SEULMENT AVEC
ATION AND
BARRIÈRE W565-0170. SUIVEZ LES INSTRUCTIONS
BARRIÈRE W5
R SERVICING
D'INSTALLATION SE TROUVENT DANS LE MANUEL
'INSTALL
D'INST
D'INSTALLATION.
R USE AS A HEATING
AV
AVERTISSEMENT: N'AJOUTEZ PAS A CET APPAREIL
AUCUN MATERIAU DEVANT ENTRER EN CONTACT
A
AVEC LES FLAMMES AUTRE QUE CELUI QUI EST
2"*
2"*
FOURNI AVEC CET APPAREIL PAR LE FABRICANT.
CE FOYER À GAZ VENTILÉS NE DOIT PAS ÊTRE
1"
1
UTILISÉ CONJOINTEMENT AVEC DES FILTRES À AIR.
CLASS:
SOUFFLERIE GS66,
115V 0.5AMP 60HZ
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT
L'ENSEMBLE D'EVACUATION PROPRE A
WOLF STEEL. REFERER AU MANUEL
D'INSTALLATION DE PROPRIETAIRE POUR
L'EVACUATION PRECISE. LES LONGUEURS
VERTICALES MINIMALES ET MAXIMALES
SONT3 PIEDS ET 35 PIEDS RESPECTIVEMENT.
* L'EXTENSION HORIZONTAL MAXIMALE 2". REFERER AU MANUEL D'INSTRUCTION POUR DES EXTENSIONS
PLUS GRANDES.
GD19
SERIAL NUMBER / NO. DESERIE
PROPANE GAS
0 - 4,500*
11,000
8,250
75%
11" (27mb) Water Column
13" (32mb) Water Column
10" (25mb Water Column
MANIFOLD PRESSURE: 10 INCHES W.C.(LP)
PRESSION AU COLLECTEUR: 10" D'UNE
COLONNE D'EAU (P)
MIN SUPPLY PRESSURE: 11" W.C. (LP)
CDV19P
PRESSION D'ALIMENTATION MIN: 11" D'UNE
COLONNE D'EAU (P)
MAX. SUPPLY PRESSURE: 13" W.C. (LP)
PRESSION D'ALIMENTATION MAX: 13" D'UNE
COLONNE D'EAU (P)
UN COMBUSTIBLE SOLIDE NE DOIT PAS
ETRE UTILSE AVEC CET APPAREIL
LES LONGUEURS HORIZONTALES MINIMALES ET
MAXIMALES SONT 8 POUCES ET 20 PIEDS
RESPECTIVEMENT.
IL EST IMPORTANT DE BIEN REINSTALLER ET
RESCELLER L'EVENT APRES AVOIR ASSURE LE
MAINTIEN DU SYSTEME DE PRISE D'AIR.
PRODUIT DÉCORATIF: NE PAS UTILISER COMME APPAREIL
DE CHAUFFAGE.
DEGAGEMENTS MINIMAUX DES MATERIAUX COMBUSTIBLES:
DESSUS
0"
MANTEAU
PLANCHER 0"
PROFONDEUR DE L'ENCLAVE 13"
COTES
0"
ÉVENT
ARRIÉRE
0"
DESSUS, COTES & ARRIERE: SELON LES ESPACEURS DE
DEGAGEMENT POUR LES MATERIAUX D'OSSATURE SELON
LE MANUEL DE PROPRIETAIRE POUR LES MATERIAUX
DE FINITION.
W385-1976
W415-1351 / 08.29.14
7
EN
2"*
1"