Selection of installation location

Basic requirement
Installing the unit in the following places may cau-
se malfunction. If it is unavoidable, please consu-
lt the local dealer:
1.
The place with strong hea t sources, vapors,
flammable or explosive gas, or volatile objects
spread in the air.
2.
The place with high-frequen cy devices (such
as welding machine, medical equipment).
3.
The place near coastal area.
4.
The place with oil or fumes in the air.
5.
The place with sulfureted gas.
6.
Other places with special circumstances.
7.
The appliance shall no t be installed in the
laundry.
8.
It's not allowed to be installed on
or motive base structure
the corrosive environment (such as chemical
factory).
Indoor unit
1.
There should be no obstruction near air inlet
and air outlet.
2.
Select a location where the condensation water
can be dispersed easily and won't affect other
people.
3.
Select a location which is convenient to conne-
ct the outdoor unit and near the power socket.
4.Select a location which is out of reach for children.
5.
The location should be able to withstand t he
weight of indoor unit and won't increase noise
and vibration.
6.
The appliance must be installed 2.5m above
floor.
7.
Don't install the indoor unit right above the ele-
ctric appliance.
8.Please try your best to keep way from fluores-
cent lamp.

Outdoor unit

1.Select a location where the noise and outflow
air emitted by the outdoor unit will not affect
neighborhood.
2.
The location should be well ventilated and dry,
in which the outdoor unit won't be exposed dir-
ectly to sunlight or strong wind.
3.
The location should be able to withstand the
weight of outdoor unit.
4.Make sure that the installation follows the req-
uirement of installation dimension diagram.
5.
Select a location which is out of reach for chil-
dren and far away from animals or plants. If it
is unavoidable, please add the fence for safety
purpose.
Safety precaution
1.
Must follow the electric safety regulations w-
hen installing the unit.
2.
According to the local safety regulations, use
qualified power supply circuit and air switch.
the unstable
(such as truck) or in

Requirements for electrical connection

3.
Make sure the power supply matches with the
requirement of air conditioner. Unstable power
supply or incorrect wiring or malfunction. Pl-
ease install proper power supply cables before
using the air conditioner.
4.Properly connect the live wire, neutral wire and
grounding wire of power socket.
5.Be sure to cut off the power supply before pr-
oceeding any work related to electricity and safety.
Do not put through the power before finishing
6.
installation.
7.If the supply cord is damaged, it must be repla-
ced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a
hazard .
8.The temperature of refrigerant circuit will be hi-
gh, please keep the interconnection cable away
from the copper tube.
9.The appliance shall be installed in accordance
with national wiring regulations.
Grounding requirement
1.The air conditioner is the first class electric
appliance. It must be properly grounded with
specialized grounding device by a professional.
Please make sure it is always grounded effecti-
vely, otherwise it may cause electric shock.
2.
The yellow-green wire in air conditioner is
grounding wire, which can 't be used for other
purposes.
3.
The grounding resistance should comply with
national electric safety regulations.
4.
The appliance must be positioned so tha t the
p l u g is accessible.
5.
An all-pole disconnection switch having a co-
ntact separation of at least 3mm in all poles
should be connected in fixed wiring.

Air switch capacity

Including an air switch with suitable capacity,
please note the following table . Air switch sh-
ould be included magne t buckle and heating
buckle function, it can protec t the circuit-short
and overload. (Caution: please do no t use the
fuse only for protecting the circuit)
Air-conditioner
09K、12K
18K
24K
14
Air switch capacity
10A
16A
25A