Signaling
AL b
Occurs when the gearmotor
AUG TRIAC
runs continuously
ERROR
AWAITING
Occurs on relighting the insert
immediately after turning it off
COOL
Occurs when the air flow
AIR FLOW
meter is disconnected. The
METER
controller does not detect the
amount of combustion air and
FAILURE
does not shut down the insert
Occurs when the insert has
SERVICE
exceeded the hours of
DUE
operation since the previous
service
ALARMS - MESSAGES
Fault
- Incorrect parameters entered
- Faulty main board
Insert still too hot to start a
lighting phase
The air flow meter connection
cable has been disconnected
The insert requires
extraordinary maintenance
Possible causes
68
Cures
Reinstatement operations
must be carried out by a
service center
Wait for the insert to cool and
repeat the lighting procedure
The insert continues its normal
operation and safety is
guaranteed by the remaining
devices. It is advisable to
contact a service center
as soon as possible
The insert continues its normal
operation. It is advisable to
contact a service center
as soon as possible
TOPFIRE 70 – TOPFIRE 80