The unit can be installed in an existing fireplace or in a special compartment built to measure and covered with
plasterboard; in any case the optional insert support can be requested.
If the compartment is accessible from the outside, position the insert with the base resting on the reference
surface of the compartment, pull out the monoblock, making sure it does not tip over, and secure the base with 8
anchors to the existing support surface; if a support surface is not available, the height-adjustable insert support
KIT, to be fixed to the floor with 8 anchors, is available on request.
If the compartment is not accessible, proceed as follows:
1 - remove the pullout part of the insert from the guides and the fixed base by undoing the 9 guide-fixing screws
each side, after pulling it out completely;
2 - fix the base in the reference compartment with 8 anchors, making sure it is flat-horizontal and perpendicular to
the outer wall;
3 - make connections to the flue A and possible combustion air inlet B (available on request) without forcing the
connection parts on the base;
4 - make the electrical connection and/or ensure that the electric cable is run safely to the external outlet;
5 - after pulling out the telescopic guides from the base, refit the monoblock on them, carrying out the procedure of
step 1 in reverse order;
6 - check the sliding of the pullout part, locking of the latch and operation of the safety
microswitch for the insert's power supply;
9 screws LH
9 screws RH
DETAIL B
B
RH side
51
Optional insert
support KIT
TOPFIRE 70 – TOPFIRE 80