Cola TOPFIRE 70 Manuel D'installation, D'utilisation Et D'entretien page 67

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Signaling
Occurs in case of a power
AL 1
failure during the operation
POWER
phase
FAILURE
AL 2
Occurs in case of a fume
FUME
temperature detection probe
fault
PROBE
AL 3
Occurs if the probe detects a
high fume temperature
HOT FUMES
AL 4
Occurs when the fume
FAN FAIL
exhaust fan is faulty
AL 5
Pellets do not ignite in the
lighting phase
NO IGNITION
AL 6
The flame goes out during the
NO PELLETS
operation phases
AL 7
Occurs in case of intervention
THERMAL
of the auger duct temperature
safety thermostat.
SAF
In the work phase the insert
AL 8
detects a pressure lower than
NO NEG
the vacuum switch threshold
PRESS
setting
AL 9
The combustion air flow has
INSUFF
dropped below a predefined
threshold
DRAFT
ALARMS - MESSAGES
Fault
Electrical system power failure
in the room where the insert is
installed
- Probe fault
- The probe is disconnected
from the board
- Overheating due to use of
the insert for too long
- The tangential fan is faulty or
not powered
- Excessive pellet load
- The fume fan is blocked
- The speed control sensor is
faulty
- No power to the fume fan
- The pellet hopper is empty.
- The heater is faulty, dirty or
incorrectly positioned.
- Incorrect pellet load setting.
- The pellet hopper is empty
- The pellet feed gearmotor is
faulty or not powered
- Overheating due to use of
the insert for too long
- Brazier clogged with
excessive accumulated ash
- The combustion chamber is
dirty
- The fume duct is blocked
- The fire door is not closed
- The overpressure valves are
open-jammed
- The vacuum switch is faulty
- The combustion chamber is
dirty
- The fume duct is blocked
- The fire door is not closed
- The overpressure valves are
open-jammed
- The air flow meter is dirty or
faulty
Possible causes
67
Cures
- Turn the insert OFF by
pressing button P4 and repeat
the lighting procedure
- Other reinstatement
operations must be carried
out by a service center
Reinstatement operations
must be carried out by a
service center
- Wait for the insert to cool and
repeat the lighting procedure
- Other reinstatement
operations must be carried out
by a service center
Reinstatement operations
must be carried out by a
service center
- Check the presence of
pellets in the hopper.
- Repeat the lighting
procedure
- Other reinstatement
operations must be carried
out by a service center
- Check the presence of
pellets in the hopper
- Repeat the lighting
procedure
- Other reinstatement
operations must be carried
out by a service center
Reset the safety thermostat by
pressing the reset button and
repeat the lighting procedure
- Check the cleanness of the
fume duct and the combustion
chamber, hermetic closure of
the door and the overpressure
valve. Then repeat the lighting
procedure
- Other reinstatement
operations must be carried out
by a service center
- Check the cleanness of the
flue
pipe,
the
combustion
chamber and the air flow
meter; hermetic closure of the
door and the overpressure
valves.
Then
repeat
lighting procedure
- Other reinstatement
operations must be carried out
by a service center
TOPFIRE 70 – TOPFIRE 80
the

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Topfire 80

Table des Matières