The insert automatically adjusts the ventilation of hot air according to the current work phase.
- Make sure to check the pellet level in the hopper so that the flame does not go out due to lack of fuel.
- Make sure the unit is off when loading pellets.
- The pellet hopper cover must always remain closed, to be opened only during fuel loading.
- The bags of pellets must be kept at least 1.5 m from the insert.
If the STANDBY mode is not activated and the set temperature is reached, or if the fume temperature has reached
the set maximum value, the LCD display shows the message MODULATE or MODULATE F and the insert activates
the flame modulation procedure without any intervention by the user.
If, on the other hand, STANDBY mode is activated, the insert activates the modulation mode for a few minutes when
the SET temperature is reached. If the temperature remains above the set value, the insert shuts down. Restart
occurs after the room temperature falls below the set value by a few degrees (default 2°C).
If the temperature increases again, above a set limit, the HOT FUMES alarm appears and the insert activates the
shutdown procedure.
During normal operation, the BRAZIER CLEANING mode is activated for several seconds at fixed intervals.
4.2.3
Shutdown
To shut down the insert, just press button P3 for about 3 seconds. The auger is immediately stopped and the fume
exhaust fan goes to high speed, with the message FINAL CLEANING appearing on the display. The fume exhaust
and air ventilation motors will remain on until the insert temperature has fallen sufficiently.
At the end of the operation the message OFF will appear on the display.
During the shutdown phase the insert cannot be restarted until the fume temperature has dropped below a fixed
value for a given time. If the on button is pressed the message AWAITING COOL will be displayed.
4.2.4
Additional remote control functions
The display on the remote control shows all the information on insert operation.
The basic functions are:
STATUS
OFF
START
PELLET LOADING
AWAITING FLAME
FLAME PRESENT
WORK
MODULATE– MODULATE F
BRAZIER CLEANING
FINAL CLEANING
STANDBY
AWAITING COOL-
The remote control has a keylock function. This is available only if enabled by the specialized technician during the
first installation.
Using the remote control it is also possible adjust the
room temperature. Press button P4 and the display
appears as shown opposite.
Then press buttons P1 and P2 to set the room
temperature, from a minimum value of 7°C to a
maximum value of 40°C.
Insert off
The initial ignition start phase is in progress
Pellet loading in progress during the ignition phase
This is the phase prior to the flame appearing.
The flame has appeared and the insert is in the heating phase
Normal work phase
Power reduced because temp. reached or high fume temp.
Automatic cleaning at regular intervals
Final insert cleaning, before shutdown
Insert off for temperature reached and awaiting request
The insert cannot be relit because awaiting cooling