4. Function and description
4.1. Generality
GB
The travflex™ 2 lifeline delivered by Tractel
consists of the following elements arranged as shown
in Figures 1 and 2 (page 3), showing a typical flexible
installation, adaptable to the site that needs to be
equipped (horizontal installation in terrace, roof or
vertical on wall or siding):
– Two end anchors (A),
– A cable tensioner with a capacity of 130 mm (B)
having a mooring spindle at each end locked by a
spring ring pin,
Description
Kit travflex™ 2 galvanised cable
Code
Kit travflex™ 2 stainless steel
cable
Code
Cable galva 5M
Cable stainless steel 5M
Cable stainless steel
Cable galva
travsmart slider
Intermediate anchor
Curve anchor kit on galvanised steel plate for mounting plate
Curve anchor kit on stainless steel plate for mounting plate
Curve anchor kit on galvanised steel plate for structure
Curve anchor kit on stainless steel plate for structure
Sign plate in aluminium
Sign plate in aluminium GB/PT/RU/PL/DK
Kit sign plate in aluminium + manual GB/PT/RU/PL/DK
Wedge socket
Quick link
Type:
Delivery:
20
®
Components
Tensioner
293629 Tension indicator
INRS absorber
Wedge socket
Sign plate in aluminium
Extremity anchor in galvanised
steel
Tensioner
293639 Tension indicator
INRS absorber
Wedge socket
Sign plate in aluminium
Extremity anchor in stainless steel
57252 Cable Galva
57262 Stainless steel cable
Optional
Standard
As required
As required ≤ max. number N
Accessory
– A tension indicator (C),
– Two shock absorbers (D),
– A stainless steel or galvanized 8 mm in diameter
cable (G), constituting the anchor line. This cable
has a sleeved loop at one end, equipped with a lug,
SAS
the other end being soldered and ground. Its length
depends on the length of lifeline to install.
– One or more intermediate anchors (E), variable in
number depending on the length of the lifeline, if it
exceeds fifteen meters,
– A quick link connector (J),
– A corner unit (H) for locking the cable end,
– One or more anchor kits for bends (I).
40742
B
66858
C
66688 D+J ()
193837 H+J ()
228745
F
100378 A+J ()
40742
B
66858
C
66688 D+J ()
193837 H+J ()
228745
F
100378 A+J ()
238497
G
277137
G
277137
G
238497
G
251349
O
100398
E
100408
I2
100418
I2
100618
I1
100628
I1
277127
F
277237
F
282317
F
193837 H+J ()
39822
J
OPS
STD
SB
SB≤N
AC
Type of installation structure
Wall
application
application
()
STD
1
-
()
STD
1
-
STD
2
-
STD
1
-
()
STD
1
-
2
-
STD
()
STD
-
1
()
STD
-
1
-
2
STD
STD
-
1
()
STD
-
1
STD
-
2
(m) STD
5
-
-
5
(m) STD
-
SB
(m) STD
(m) STD
SB
-
SB
()
STD
SB≤3 SB≤3
SB≤3
()
STD
SB
SB
SB
()
OPS
-
-
SB
-
-
()
OPS
-
-
SB
-
-
()
OPS
SB
SB
SB
()
OPS
SB
SB
SB
SB
SB
SB
()
OPS
AC
SB
SB
SB
()
AC
SB
SB
SB
Floor
1
-
1
-
2
-
1
-
1
-
2
-
-
1
-
1
-
2
-
1
-
1
-
2
5
-
-
5
-
SB
-
SB≤3
SB
-
-
SB
-
-
SB
SB
SB
SB
SB
SB