HYDAC ELECTRONIC ETS 1700 Mode D'emploi page 29

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Setting
Primary display (Primary)
Display value which should remain
permanently in the display:
"ACT.":
"S.P.1" .. "S.P.4":
"MAX":
Determining the display range
(RANGE)
"°C":
The temperature is displayed in °C.
"°F":
The temperature is displayed in °F.
"FREE": The display range can be defined
by the user. If this setting is
selected, then decimal places and
upper and lower display range
must be set. (see below)
Display the unit (Unit)
(only when set to "RANG"=
"°C" or "°F")
If set to "YES" the pre-set unit will be
displayed briefly every 7 seconds.
Decimal places (Point)
(only when set to "RANG"="FREE")
Number of decimal places which the
ETS 1700 displays.
Lower display range (Range Low)
(only when set to "RANG"="FREE")
Lower display range limit
Upper display range (Range High)
(only when set to "RANG"="FREE")
Upper display range limit
current temperature
switching point 1 .. 4
maximum value
Display
Setting
range
ACT/
S.P.1..
S.P.4/
MAX
°C /
°F /
FREE
YES/NO
0 ..
0.000
-995 ..
9995
-995 ..
9995
Pre-
setting
ACT.
E
°C
NO
0.0
0.0
measur-
ing range
final value
29

Publicité

Table des Matières
loading

Table des Matières