Tab. 5:
Inputs
Abkürzungen
Connections
Inputs
Te.
Ident.
Signal
X8
5 – 6
Open signal
drive
impulse
access
X9
8 – 7
Day signal
drive
access
X9
8 – 7
Open signal
e-drive
Handle
e-access
engaged
X10
9 – 10
Radar signal
X11
11 – 12 Locked/block
signal
X12
13 – 14 Permanently
open signal
X13
15 – 16 Ext. door
contact
X14
38 – 39 Fire alarm
system (FAS)
X15
40
12 V DC /
41
24 V DC
GND
LED
Function
LED 2 Contact open: night operating mode
Contact closed: release operating
mode (open/released)
LED 3 Contact open: right operating mode
Contact closed: "secured" day, bolt
retracted 70 % => tilt latches rigid
LED 3 Contact open: night operating mode
Contact closed: is motorised engaged
on the panic opposite side
LED 4 Only in operation if day or perma-
nently open is bridged.
Contact closed: lock moves into open
position DD 1.5 sec.
LED 5 All inputs X8−X12 without function
LED 6 Contact open: night operating mode
Contact closed: operating mode
permanent release without door drive
impulse, lock is in open position
LED 7 External door contact (TC)
Connection fire alarm system
with potential-free contact or as
12 V / 24 V supply voltage
LED 1 Operating voltage stabilised DC for
motorised lock and display for faults
(see DIP switch)