X17 Output without fuse
42 Plus like 40 without fuse
43 GND (like 41)
X18 Interface
RS 485 (Mod-Bus)
44 A
45 B
Jumper
JP2
Fire alarm system
configuration
JP3/4 120 Ω RS 485
X19 Programming
interface
Service button
Query of the cycles,
fault analysis etc.
(see Dip switch)
X10 Radar drive/access
e-drive/e-access
10 GND
9
Lock moves into
open position
door drive 1.5 sec.,
input only active if
X12 or X9 is active.
X11 Locked
12 GND
11 All inputs are inactive,
lock locked
X12 Permanently open
14 GND
13 Permanent release lock
without actuation door drive (X1)
=> tilt latches soft
X13 Ext. door contact
16 GND
15 Monitoring contact (break contact)
manufacturer recommendation
(Bridged in delivery state)
Fig. 3 : Configuration e-access
EN
42
Configuration e-access
X14 Fire alarm system
38 NC
39 COM
X
If no fire alarm system is used,
insert a bridge. (Default state)
X18 X17
Fuse
LED 15
45 44 43 42
JP4
JP3
Service
1 2 3 4
X16
X16 Lock
1
Cable red plus
2
Cable black GND
3
Cable green A
4
Cable yellow B
X6 Relay panic handle
PBa – DIN right
PBe – DIN left
X7 Relay handle panic opposite side
PBe - DIN right
PBa - DIN left
X15 X14
41 40 39 38
JP2
LED 13
LED 12
LED 11
LED 10
LED 9
LED 8
X19
Update
LED 1
LED 2 LED 3 LED 4 LED 5 LED 6 LED 7
5 6 7 8
9 10 11 12 13 14 15 16
X8
X9 X10 X11 X12 X13
X15 Supply
40 Plus 12 V/24 V DC (stabilised)
41 GND
LED 14
X1–X7 Outputs
37
Relay door drive X1
X1
36
35
Relais Störung X2
X2
34
33
Relay fault X3
32
X3
31
30
Relay cylinder X4
29
28
X4
27
26
Relay bolt X5
25
X5
24
23
Relay handle status X6
22
X6
21
20
Relay handle status X7
19
X7
18
17
X8 Open signal impulse e-drive/e-access
100% open
6
GND
5
Impulse input (open/released)
with door drive
X9 Open signal day e-drive/e-access
7
GND
8
Impulse/permanently open
lock engages panic opposite side
motorised. Without door drive.
37
NO
36
COM
35
NO
34
COM
33
NO
32
COM
31
NO
30
COM
29
NC
28
COM
27
NO
26
COM
25
NO
24
COM
23
NC
22
NO
21
COM
20
NC
19
NO
18
COM
17
NC
Abkürzungen