Key:
Imp. button
Door contact (Reed)
Door contact
Permanent
opening
Locked
Radar
Day
Impulse
GND
LED operation
Flashes in the event of a fault
BT
B
A
GND
+24 V
1 2 3 4 5 6 7 8
DIP switch
Functions of the DIP switch,
see page 9
Abkürzungen
Key switch
Electronic
access control
(Reader)
LED status inputs
Inputs
16
X13
15
14
X12
13
12
X11
11
10
X10
9
8
X9
7
6
X8
5
white
yw
4
yellow
3
gn
X16
2
bw
1
rd
6 pin connection cable
ON
LIYY 2x2x0.22 + 2x0.5
MSL art. 10/20m 14471403/04
OFF
DIP 2 OFF = fail-locked (closed in de-energized state)
DIP 2 ON = fail-unlocked (open in de-energized state)
Timer ext.
DAY/NIGHT
Radar on door
Reserve
®
sFlipLock
/
brown
®
mFlipLock
green
black
1
2
red
ON
Ext. door contact:
Monitoring contact
(break contact) manu.
recommendation (bolt
protection function)
Permanent opening:
Permanent release
sFlipLock/FlipLock
without control door
drive (X1)
Tilt latches soft!
Locked:
All inputs are inactive.
sFlipLock/FlipLock
locked!
Motorised release:
Released/tilt latch soft
Input only active if
permanently OPEN or
DAY door drive (X1)
Impulse 1.5 sec.
Day function:
Panic opposite side
Couple
Bolts are
retracted 70 %
Tilt latches rigid!
While impulse is present
= coupling time panic
opposite side coupled
Impulse: Release
Released/tilt latch
soft! Impulse and
permanent release
Door drive (X1) actuated
while input "impulse"
active!
If DIP5 ON and DIP6 OFF,
door drive (X1) 1.5 sec.
Key switch:
e.g. door drive
Ventilation/
permanently open
DIP5 and DIP6 OFF
Impulse and timer:
E.g. via a supply line
Door drive (X1)
impulse 1.5 sec.
DIP5 ON and DIP6 OFF