Door contact (Reed)
LED status inputs
Inputs
16
X13
Door contact
15
14
X12
manent opening
13
12
X11
Locked
11
10
X10
9
Radar
8
X9
Day
7
6
X8
Impulse
5
Flashes in the event of a fault
BT
4
B
3
A
X16
2
GND
1
+24 V
ON
OFF
1 2 3 4 5 6 7 8
DIP switch
Functions of the DIP switch,
see page 9
Abkürzungen
Electronic
access control
Radar on door
(Reader)
(Factory setting)
Terminal 16 and 15 bridged
Reserve
white
yw
brown
yellow
gn
green
bw
black
rd
red
6 pin connection cable
LIYY 2x2x0.22 + 2x0.5
MSL art. 10/20m 14471403/04
Outer radar
®
/
sFlipLock
®
mFlipLock
Internal radar
Permanent release
sFlipLock/FlipLock
without control door
drive (X1)
Tilt latches soft!
Locked:
All inputs are
inactive
sFlipLock/FlipLock
locked!
Radar:
Input only active if
Radar
permanently OPEN
or DAY operation
DD impulse 1.5 sec.
Day function:
Bolts are
retracted 70%
Tilt latches rigid!
Impulse:
Impulse and
permanent release.
Door drive (X1)
actuated while input
"impulse" active!
If DIP5 ON and
DIP6 OFF,
door drive (X1) 1.5 sec.
Key switch:
e.g. door drive
Ventilation/
permanently open
DIP5 and DIP6 OFF
Impulse and timer:
E.g. via a supply line
Door drive (X1)
Radar
impulse 1.5 sec.
DIP5 ON and DIP6 OFF
EN
55