Press the
button again to turn the open window detection off. The icon disappears
from the display and the unit returns to its previous settings.
If the heater is set to come on in a weekly programme and you turn the open window
detection on, this will only work while the unit is switched on in the weekly programme.
Overheating protection
The overheating protection system switches the unit off if it gets too hot. This will happen if
the unit is unable to get rid of enough heat or if it cannot take in enough fresh air. Common
reasons for this are that the unit has been partially or completely covered, the intake/outlet
roosters are blocked or the unit has been placed too close to a wall. If the overheating
protection is activated and the unit switches off, the unit will start to ventilate to get rid of
the extra heat. In this case, the display does not change. Once the unit has cooled down, it
will return to its previous setting. We advise you to switch the unit off using the remote
control and to give it enough time to cool down. Once you have removed the cause of the
overheating, you can use the unit again as normal. If you cannot find the cause of the
overheating and the unit continues to overheat, you should turn the unit off and return it for
repair.
Cleaning and Maintenance
Keep the heater clean. Deposits of dust and dirt in the appliance are a common cause of
overheating so these should be removed regularly. Switch off the heater, remove the plug
from the socket and allow the heater to cool down before cleaning or carrying out
maintenance work.
Wipe the outside of the heater regularly with a dry or slightly damp cloth. Do not use
aggressive soaps, sprays, cleaners or abrasives, waxes, polishes or chemical
solutions!
Using a vacuum cleaner, carefully remove any dust and dirt from the grills and ensure
that the air intake and outlet openings are clean. Be careful not to touch or damage
any internal parts during cleaning!
The heater contains no other parts which need maintenance.
At the end of the season, store the cleaned heater in the original packaging if possible.
Store upright in a cool, dry and dust-free place.
Do not dispose of heater with household waste when if becomes worn or damaged
beyond repair. Take it to your local authority's collection point for electrical appliances
where any reusable materials will be collected and redistributed.
CE-statement
Eurom - Genemuiden-NL hereby declares that the EUROM Ceramic wall heater with
remote control,
type WALL DESIGNHEAT 2000R, complies with the LVD guideline 2014/35/EU and the
EMC guideline 2014/30/EU, and that it meets the following standards:
EN 60335-1:2012+A11:2014
EN 60335-2-30:2009+A11:2012
EN 62233:2008
Rohs 2011/65/EU
Genemuiden, 26-04-2016
W.J. Bakker, alg. dir.
EN 55014-1:2006+A1:2009+A2:2011
EN 55014-2 :1997+A1:2001+A2:2008
EN 61000-3-2:2014
EN 61000-3-3:2013