Check whether the heater is secured to the wall; if necessary insert the screws a little
further into the plugs.
Attach the heater using the materials supplied. Place the
bracket on top of the heater (see picture) with the short
side against the wall. Mark the location of the hole on the
wall and remove the heater. Drill a hole at the marked spot
and insert a plug. Now hang the heater in place and screw
the bracket to the wall, as shown in the diagram. The
heater is now installed.
Using for the first time and Operation
Make sure that the main switch is OFF (O)
Unroll the electrical cable entirely and insert the plug into a suitable
220/240V socket.
Set the main switch to ON (l). The display will show "S" (standby).
Manual operation using the buttons:
Press the F button once. The ventilator will switch on and the display will
show Fig. A.
Press the button again and the heating will switch on, on low power. The
display will show Fig. B.
Press the button a third time and the heating
will switch to full power. The display will
show Fig. C.
Press the button a fourth time and the swivel
function switches on. The display continues
to show Fig. C.
Press the button a fifth time and the unit
returns to standby (S). The unit will cool
down for 30 minutes.
You can set a delayed start time using the
timer button
Each time you press the timer button, one hour is added to the start time.
The display shows the number of hours set and counts down at the end of
each hour. The timer lamp also switches on. The unit starts automatically
at the end of the set time. The standard temperature is 23°C (note it is not
possible to set the thermostat using the buttons).
If the weekly programme is not set and if no temperature has been set
using the remote control, the unit will switch off automatically after 12
hours.
Operation using the remote control:
Please note: the remote control only works if the emitter on the remote
control can make contact with the receiver on the unit.
Make sure that the unit is in standby mode (S) (use the main switch).
Press the power button
show Fig. A.
Press the function button
display will show Fig. B.
. Set the unit to standby (S) and press the timer button.
to switch the ventilator on; the display will
to switch the heating on, on low power. The