Safety warning!
For the illustration, see page 99.
2. INSTALLATION
Instructions which must be followed by the drive and home automation professional installing the Movelite
motor.
Never drop, knock, drill or submerge the drive.
Install a separate control point for each drive.
2.1. INSTALLATION
2.1.1. Installation of the rail (Fig A)
1) Mark the position of the brackets.
2) Drill the ceiling or the wall at the right places.
3) Attach the brackets.
4) Attach the rail on the brackets.
2.2. WIRING
(Fig C)
Cables which pass through a metal wall must be protected and isolated using a sheath or sleeve.
Attach cables to prevent any contact with moving parts.
Leave the drive power supply cable accessible: it must be possible to replace it easily.
Switch off the power supply.
-
Connect the drive according to the information in the table below:
-
AC wiring
(Fig C1)
Wire
1
Neutral
2
Live
3
Live
4
Earth
Never connect 2 control points to a single drive
DCT wiring
(Fig C3)
1
CCW (Open) NO Dry contact
2
3
Ground Common
Compatible controls - Wiring of control
1) Inis Uno
2) Série espace
3) Centralis Uno IB
4) Setting tool
2.3. COMMISSIONING
Setting can be done only when one of the two live wires are connected permanently to the power.
2.3.1. Setting the end limits
1) Switch on the power supply.
2) After the first Open or Close command, the motorised product will run at reduced speed to one end, then the
other, to set the End Stops.
Copyright © 2018 SOMFY ACTIVITÉS SA, Société Anonyme. All rights reserved.
Caution!
2.1.2. Installation of the motor (Fig B)
1) Unlock the motor
2) Insert the motor shaft into the drive pulley hole.
3) Lock the motor.
100V to 240V
Blue
Brown
Black
Yellow / Green
(Fig C2)
4
5
Stop - NO Dry contact
6
CW (Close) NO Dry contact
(Fig D)
EN
Information
TM