12
Technical Data
Operating Range ................................. Fittings up to 450 mm
Nominal Voltage ................................... 230 V
Frequency ............................................ 50 Hz / 60 Hz
Power ................................................... 2800 VA, 80% duty cy
Protection Index ................................... IP 54
Primary Current ................................... 16 A
Ambient Temperature .......................... – 20°C to + 60°C (– 4°F bis + 140°F)
Output Voltage ..................................... 8 V - 48 V
Max. Output Current ............................ 95 A
Memory for Welding Reports ............... 5000 reports
Data Interface Port ............................... USB v 2.0 (480 mbit/s)
(see also the information on the data ports in Sect. 6)
Tolerances:
Temperature .................................. ± 5 %
Voltage .......................................... ± 2 %
Current .......................................... ± 2 %
Resistance .................................... ± 5 %
13
Customer service
The ROTHENBERGER service locations are available to help you (see listing in
catalog or on-line) and replacement parts and service are also available through these
same service locations.
Order your accessories and spare parts from your specialist retailer or using our
service-after-sales hotline:
Phone: + 49 (0) 61 95 / 800 – 8200
Fax:
+ 49 (0) 61 95 / 800 – 7491
Email: service@rothenberger.com
www.rothenberger.com
14
Disposal
Components of the unit are recyclable material and should be put to recycling. For
this purpose registered and certified recycling companies are available. For an
environmentalfriendly disposal of the non-recyclable parts (e.g. electronic waste) please
contact your local waste disposal authority.
For EU countries only:
Do not dispose of electric tools with domestic waste. In accordance with European
Directive 2012/19/EU on waste electrical and electronic equipment and its
implementation as national law, electric tools that are no longer serviceable must be
collected separately and utilised for environmentally compatible recycling.
ENGLISH
29