General Connections - Iberspa SM-COM-PR Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 70
The compact equipment should be below the level of the Spa. This will avoid having to
prime the pumps. It should be a maximum of 3 o 4 metres below the Spa.

4.3. General connections

PIPING
The following type of piping should be used for the connection:
• Filtering circuit: PN 10 diameter 50 mm*
• Massage circuit (jets): PN 10 diameter 63 mm*
• Air massage circuit: PN 10 diameter 50 mm*
*On standard distance (maximums 7 m) and without losing power charge.
Follow the diagrams and assembly instructions given below for each circuit.
In any event, the installation of bends and piping should be reduced to a minimum in
order to reduce the load loss of the installation.
Always use plastic accessories, gasket and teflon tape for the selector valve connections.
Never use steel accessories or piping as they could seriously damage the plastic
components.
CIRCUIT DETAIL
AIR INJECTORS
DRAIN 1
BLOWER PUMP
MASSAGE
PUMP 1 INLET
PUMP 1 OUTLET
h
2m
4m
DESCRIPTION OF SPA CONNECTION SYSTEM
JETS 1
IMPULSE
JETS 2
MASSAGE
HEATING
MASSAGE
OUTPUT
PUMP 2 OUTLET
042
DRAIN 2
SKIMMER
BOTTOM
CLEANER
MASSAGE
FILTERING
PUMP 2 INLET
PUMP INLET
ENG
DRAIN 3
043
9

Publicité

Table des Matières
loading

Table des Matières