MODE READY & REST / READY IN REST MODE
In order for the spa to heat, a pump needs to circulate water through the heater. The
pump that performs this function is known as the "heater pump." The heater pump can
be either a 2-Speed Pump 1 or a circulation pump. READY Mode will circulate water
every 1/2 hour, using Pump 1 Low, in order to maintain a constant water temperature,
heat as needed, and refresh the temperature display. This is known as "polling."
REST Mode will only allow heating during programmed filter cycles. Since polling
does not occur, the temperature display may not show a current temperature until
the heater pump has been running for a minute or two.
If the spa is configured for 24HR circulation, the heater pump generally runs
continuously. Since the heater pump is always running, the spa will maintain set
temperature and heat as needed in Ready Mode, without polling.
In Rest Mode, the spa will only heat to set temperature during programmed filter
times, even though the water is being filtered constantly when in Circulation Mode.
Main Screen
To next item in
Main Menu
Toggle between READY and REST
If not toggled
Pressing Light when the display is toggled will go to Main Screen.
READY Mode will allow the spa to Poll and determine a need for heat. The panel will maintain a "current" temperature display.
Main Screen
1 Hour
The Main Screen will display RUN PUMP FOR TEMP if the filtration pump has not run for over 1 hour.
The Main Screen will display normally during Filter Cycles or when the spa is in use.
If the filtration pump has been off for an hour or more, when any function button, EXCEPT Light, is pressed on the panel, the pump used in
conjuncton with the heater will run so that temperature can be sensed and displayed.
READY-IN-REST MODE
READY/REST appears in the display if the spa is in Rest Mode and Jet 1 is pressed. It
is assumed that the spa is being used and will heat to set temperature. While Pump 1
High can be turned on and off, Pump 1 Low will run until set temperature is reached,
or 1 hour has passed. After 1 hour, the System will revert to Rest Mode. This mode can
also be reset by entering the Mode Menu and changing the Mode.
22
While the Temperature is still
flashing, press Light repeatedly
until MODE appears in the LCD.
To Set
*****
Waiting
Several Seconds
Reverts to Original Setting
REST Mode will not Poll and will only heat during filter cycles. The panel will not display a current temperature at all times.
| TP600
| TP600
Main Screen
KEY
Indicates Flashing or Changing Segment
Indicates Alternating or Progressive Message -
every 1/2 second
A temperature button, used for "Action"
Light or dedicated "Choose" button, depending
on control panel configuration
Waiting time that keeps the last change to a
menu item.
Waiting time (depends on menu item) that reverts
*****
to original setting and ignores any change to that
menu item.