SWITCHING THE POWER SUPPLY OF THE EQUIPMENT ON/OFF

To connect the equipment to the power supply, it should be connected to the electrical
supply, placing the differential switch in the ON position. To switch it off, place in the OFF
position.

WATER FILTERING

Filtering is controlled automatically by the pre-programmed filtering cycles or when the
system detects a reduction in temperature and activates the system to heat the water.
When the kit is operating normally, the Automatic-Manual Selector should always be in
the automatic position.
The Automatic–Manual Selector should always be in the automatic position when the kit
is operating normally, otherwise the digital system will commit errors which could lead to
significant damage of the equipment.
Put the selector valve in the FILTERING position to let the sand retain the particles while
water is passing.
HOW TO EMPTY THE SPA
The compact equipment can empty the Spa. To do this, follow these steps:
• Open the valves of the circuits that by-pass water to the drain.
• Turn off the Filtering Pump by placing the selector in the OFF position.
• Place the selector valve in the EMPTYING position.
• Turn on the Filtering Pump by placing the selector in the Manual position.
• Once the Spa is empty, turn off the filtering pump by placing the selector in the OFF
position and disconnect the equipment from the power supply.
• To refill the spa, place the valves in their normal position.
ATTENTION
When the water level in the Spa is insufficient for the pump to suck water, must
shut the pump by turning the selector to the OFF position. If the pump works
without water would suffer major damage. Emptying will drain through.
18