PRIMING MODE - M019
| TP600
This mode will last for 4-5 minutes or you can manually exit the priming mode after
the pump(s) have primed.
Regardless of whether the priming mode ends automatically or you manually exit the
priming mode, the system will automatically return to normal heating and filtering
at the end of the priming mode. During the priming mode, the heater is disabled to
allow the priming process to be completed without the possibility of energizing the
heater under low-flow or no-flow conditions. Nothing comes on automatically, but
the pump(s) can be energized by pushing the "Jet" buttons.If the spa has a Circ Pump,
it can be activated by pressing the "Light" button during Priming Mode.
You can manually exit Priming Mode by pressing a "Temp" button (Up or Down). Note
that if you do not manually exit the priming mode as described above, the priming
mode will be automatically terminated after 4-5 minutes. Be sure that the pump(s)
have been primed by this time.
Once the system has exited Priming Mode, the top-side panel will momentarily
display the set temperature but the displaywill not show the temperature yet, as
shown below. This is because the system requires approximately 1 minute of water
flowing through the heater to determine the water temperature and display it.
ADJUSTING THE SET TEMPERATURE
| TP600
When using a panel with Up and Down buttons (Temperature buttons), pressing Up
or Down will cause the temperature to flash. Pressing a temperature button again will
adjust the set temperature in the direction indicated on the button. When the LCD
stops flashing, the spa will heat to the new set temperature when required.
If a Temperature button is pressed and held when the temperature is flashing, the
temperature will continue to change until the button is released.