Make sure that there is no electrical current in the connection cable (differential switch in
the OFF position).
Take the cable to the panel of the Kit.
SINGLE LINE (1 X 16 A) LOWAMP OR (1 X 32 A) HIGHAMP:
Open the cabinet of the Automatic - Manual Selector, insert the cable through the free
packing gland and connect the Neutral marked with N, the line or phase to the terminal
marked L and the earth in the special, green and yellow, earth terminal.
With the HIGH AMP option, the heater of the compact equipment always operates when
temperature is required (meaning a higher electrical consumption).
With the LOW AMP option, the heater is limited to the filtering cycles (reducing electrical
consumption to a minimum).
WARNING
Correct earthing connection is essential
The earthing circuit of the building should be in perfect condition at all times
to guarantee the safety of the Spa user. If you have any doubts, ensure that the
earthing circuit is checked by qualified professionals. The manufacturer is not
liable for any possible damage or risks caused by unsuitable maintenance of
the earthing circuit.