4. INSTALLATION
4.1. Power supply interruptions
Should the power supply be interrupted, the system will always automatically restart in
the operating mode it was in before the interruption.
ATTENTION
After a Power supply interruption the filtration pump will start automatically.
Make sure the hydraulic circuit is ready or connect/disconnect necessary
items before the power supply will return.
4.2. ESD Warning
The following precautions must be taken:
Do not open the protective conductive packaging until you are at an approved anti-static
work station and have read the following. Use a conductive wrist strap attached to a good
earth ground.
Always discharge yourself by touching a grounded bare metal surface or approved anti-
static mat before picking up an ESD-sensitive electronic component. Use an approved
anti-static mat to cover your work surface. Avoid packaging the PCB into plastic bags,
polystyrene or non-antistatic bubble films.
ATTENTION
This product uses components that can be damaged by electrostatic
discharge (ESD). When handling, care must be taken so that the devices are
not damaged. Damage due to inappropriate handling is not covered by the
warranty.
4.3. Electrical connections
Some advices to take into account before doing electrical connections:
• Pumps neutral wire remains free.
• Make sure the power supply is unconnected before starting the installation procedure.
• Respect indicated cable sections and distance between components.
To ensure a proper management of the electronic signals the distance between the
components should not exceed the following:
Electronic push buttons - Electronic Board ................................................................................................15m
Spa-Hydraulic kit (Pumps) ............................................................................................................................................. 7m
ENG