Travis Industries ProBuilder 54 Linear Manuel D'installation page 54

Table des Matières

Publicité

54
9. Retirez le régulateur de l'avant de la vanne de régulation de gaz. Remplacez-le par le régulateur de propane,
en utilisant le nouveau joint et les vis fournies avec le régulateur REMARQUE: La fuite teste cette zone
après l'installation du radiateur, le gaz est connecté et le brûleur principal est allumé.
a
Remove and discard the three
screws using a slotted screwdriver
of Torx T-20.
Slotted
Screwdriver
(or T-20 Torx)
c
Install the LP regulator. Use
the screws included with the
LP regulator. Tighten to
approximately 25 Lbs. torque.
Slotted
Screwdriver
(or T-20 Torx)
© Travis Industries
Installation
(for qualified installers only)
b
Remove and discard the
regulator, diaphram, spring
and center post.
NOTE: Make sure the
regulator gasket is correctly
aligned before installation.
d
Place the LP
label on the base
near the gas
control valve.
Replace the regulator following the instructions included
with the regulator kit. Remove and discard the screws (see
"a" below) holding the stock regulator in place (see "b"
below). Remove the stock regulator and gasket (see "c"
below). Place the LP regulator in place, making sure the
pre-fitted gasket (see"c" below) is in place – make sure it
is correctly oriented. Secure using the screws included
with the motor – tighten to 25 Lb-inches. Leak test this
area after installation to verify proper installation.
There is a label on the base of the regulator knob indicating
regulator type (NG or LP). Place the included label on the
valve body where it can be easily seen to insure proper
identification ("d").
a
b
d
4170530
T-20 Torx or
Slotted Screwdriver
c
100-01455