Introduction
Purpose
This Field Service Bulletin describes the procedures for installing the optional Eliminizer air filter kit (for moisture removal)
and replacing the Eliminizer filter element on the following systems: Powermax350/380, Powermax600/800/900,
Powermax1000/1100/1250/1650, and MAX43.
If you have a Powermax30/30 XP/45/45 XP/65/85/105/125, search for Field Service Bulletin 804180
at www.hypertherm.com/docs.
Optional air filters
Powermax gas specifications call for the use of clean, dry, and oil-free air. The best defense against gas line
contamination is to keep the air compressor in good working condition. If work site conditions introduce excess humidity
or oil, use additional air filtration.
The optional Eliminizer air filter removes moisture and dirt from the gas supply.
To remove oil and oil vapor from the gas supply, use an oil removal filter, such as kit 428719 (not included).
Optional air filters may increase the required minimum inlet pressure.
Powermax Legacy Systems Field Service Bulletin 809620
Optional Air Filter Kit and Element Replacement Procedure
Disconnect electrical power before performing any maintenance.
All work requiring removal of the power supply cover must be performed by
a qualified technician.
See the safety information provided with your product for more safety
precautions.
WARNING!
ELECTRIC SHOCK CAN KILL