Sommaire des Matières pour Hypertherm POWERMAX1650 PFC IGBT
Page 1
Powermax1650 PFC IGBT Replacement Remplacement de la Powermax1650 PFC IGBT Field Service Bulletin Bulletin de service sur le terrain 804640– Revision 3 – November, 2008 Révision 3 – Novembre, 2008...
Page 2
POWERMAX1650 PFC IGBT REPLACEMENT DANGER ELECTRIC SHOCK CAN KILL Disconnect electrical power before performing any maintenance. See Section 1 of the Operator Manual for more safety precautions. Introduction Purpose Describes necessary steps to replace the PFC IGBT in the Powermax1650.
Page 3
POWERMAX1650 PFC IGBT REPLACEMENT Installation 1. Remove and discard the old PFC IGBT and mounting screws (4). 2. Remove the old thermal grease with isopropyl alcohol. 3. Apply a thin coat of grey thermal grease (Part number 128836) to the PFC IGBT (Part number 109320) mounting surface.
Page 4
REMPLACEMENT DE LA POWERMAX1650 PFC IGBT DANGER DANGER DʼÉLECTROCUTION Toujours couper lʼalimentation électrique avant de procéder à toute opération dʼentretien. Voir la Section 1 du Manuel de lʼopérateur où lʼon donne davantage de mesures de sécurité. Introduction Objet Description des étapes nécessaires pour remplacer le PFC IGBT dans le Powermax1650.
Page 5
REMPLACEMENT DE LA POWERMAX1650 PFC IGBT Installation 1. Enlever et mettre au rebut le vieux PFC IGBT et les 4 vis de montage. 2. Enlever la vieille graisse thermique avec de lʼisopropanol 3. Passer une fine couche de graisse thermique grise (réf. 128836) au PFC IGBT (réf. 109320) surface de montage.
Page 6
Hypertherm and Powermax are trademarks of Hypertherm, Inc. and may be registered in the United States and/or other countries. Hypertherm et Powermax sont des marque de commerce dʼHypertherm, Inc. et peut être déposée aux États-Unis et/ou dans dʼautres pays. Hypertherm, Inc.