D Set the parameters to be coherent with the network to which the
device is connected . It is also necessary to set the DNS for connec-
tivity with CameConnect .
E Port to connect the PC for programming with PXManager .
F Choice of keypad to duplicate .
As well as providing connection to CameConnect for remote man-
agement, accessory PXDGETH also allows the control unit to be
connected to a local network so that it can be managed from Came
TouchScreens and smartphones with the Came Domotic app con-
nected to the same local network .
CameConnect connectivity via WIFI [WIFI]
When connecting to CameConnect via WiFi accessory PXDGWF
must be used . In this case it is necessary to connect the module to
the user's WiFi network .
In default settings the WiFi is set up as Access Point C so that the
PIR Camera sensors (IR sensors relating to videocheck) or other
network devices can connect to it directly .
- The default SSID is "CameSecurity-xxxxx" (Where xxx are the last
4 digits of the Keycode)
- Password: <Random string of 16 characters>
The WiFi data are written on the label inside the package .
001SIGPRS
560121
Keycode: 577A13EEFA6F1D27
The device's WiFi network is hidden, so is not visible during
WiFi SSID:CameSecurity - 1D27
scanning . To connect to the WiFi network you must enter the SSID/
WiFi Pass:qtEc35vtggBqgQwc
Password credentials (see operating system manual of PC you are
PXGPRS
560121
Keycode: 577A13EEFA6F1D27
WiFi SSID:CameSecurity - 1D27
WiFi Pass:qtEc35vtggBqgQwc
working on) .
To connect to the WiFi network you must enter the SSID/Password
credentials (see operating system manual) .
To connect the GSM module to a domestic WiFi network you must:
A Select [WIFI] from the types of connection .
B Select [Connectivity] [WIFI] .
4
A
B
C
5
F
G
C Deselect [Access point mode] so as to set the WiFi mode as
'Station' .
D Enter [SSID] and select the type of [PROTECTION] of the Cus-
tomer's network .
E Enter the [PASSWORD] of the Customer's network .
F Enable if the customer's network has a DHCP Server . In this way
module PXGPRS automatically acquires the network parameters .
When programming with DHCP, if a reading is taken of the
control unit's settings, the IP address/Netmask fields show the ad-
dress acquired dynamically by the interface .
If the customer's network does NOT have a DHCP Server, disable
function f and manually enter the parameters relating to the cus-
tomer's network G .
As well as providing connection to CameConnect for remote man-
agement, accessory PXDGWF also allows the control unit to be con-
nected to a local network so that it can be managed from Came
TouchScreens and smartphones with the Came Domotic app con-
nected to the same local network .