Start up programming
1 .
The control unit must be totally off .
2 .
If the PROGRAM . FROM PC parameter is:
, start up programming .
WITH CTL-U. OFF
, before starting up programming enter the
AFTER USER CODE
user code .
3 .
Open the programming window, select the parameters to start
up and press start writing .
Warning: the control unit is Autobauding and could require sev-
eral seconds to synchronise .

Restore system

Restoring parameters is irreversible and cancels all
programming but not the events memory .
To reset the control unit completely you need to both reset
the factory settings and restore the codes .

Restoring codes

After restoring the system, all of the codes will be deleted and the
User Code 001 will go back to 123456 .
Before opening the control unit cover, refer to "OPENING/CLOSING
CONTROL UNIT" .
To restore factory-set codes, you have to:
1 .
Set Dip 2 to ON .
2 .
Press button P1 to make the control unit restart .
3 .
The words
appear on the keypad (this remains dis-
SETTING UP
played for 10") .
4 .
For the 10" that the keypad displays
5 .
The words
SETTING UP IN PROCESS
6 .
At the end of setting up, the control unit returns to displaying
the system status .
SETTING UP
, set Dip 2 to OFF .
SETTING UP
appear on the keypad .
SETTING UP
IN PROCESS
Once programming is completed, restore the system to service, as
explained in the section "SYSTEM IN MAINTENANCE / SERVICE" .

Factory settings

To restore all the input and output parameters, telephone notifica-
tions etc . to factory settings, you have to:
1 .
Go into the Technical Menu .
(
)/(
)
2 .
With
select
DEFAULT PARAMETERS
(A)
(#)
3 .
With
confirm or
to cancel .
The default parameters do not delete the codes and keys that
have been acquired .

Factory settings via dip-switch

To restore factory-set codes, you have to:
1 .
Set Dip 3 to ON .
2 .
Press button P1 to make the control unit restart .
3 .
The words
appear on the keypad (this remains dis-
SETTING UP
played for 10") .
4 .
For the 10" that the keypad displays
5 .
The words
SETTING UP IN PROCESS
6 .
At the end of setting up, the control unit will return to its fac-
tory settings (including codes and keys) .
and press (*) .
SETTING UP
, set Dip 2 to OFF .
SETTING UP
appear on the keypad .
SETTING UP
IN PROCESS