Sortie CAN SAE J1939
Setup
Peer-to-peer message (PGN 0x00EF00), send/receive format
PGN
PGN
PGN
(Node-ID)
HIGH
Request: Control Unit → Sensor
0EFh
Response: Control Unit ← Sensor
0EFh
a:
Acknowledge codes:
0: Acknowledge, 81: Read only parameter, 82: Range overflow,
83: Range underflow, 84: Parameter does not exist
dd:
Sensor Node-ID (Default 0F7h, 247d)
cc:
Control-Unit Node-ID
32
MAN-WB-F-16
Warning notice
• Changing the parameters can cause a sudden step of the instantaneous
value and can result in unexpected machine (re)actions!
• Precautions to prevent danger for man or machine are necessary!
• Execute parametrizing at standstill of the machine only!
Node-ID
The default Node-ID the sensor will claim on power up is user or factory
configurable. The user can configure by "Commanded Address" service
according to the J1939 standard or by Peer-to-Peer message as described
below.
User configuration
User accessible parameters including node-id may be configured by peer-
to-peer proprietary A message PGN 0EF00h. The parameters are a ccessed
by byte-index and read/write operations coded in the data f rame. The s lave
will return the data frame including the acknowledge code. Parameter
v alues will be effective immediatly. On execution of "Store Parameters" the
configuration is saved nonvolatile.
Index
Rd/Wr
LOW
dd
i
0/1
cc
i
0/1
www.asm-sensor.fr Tél.: +33 3 88 49 25 35
8 Byte data frame
0
Ack
0
0
LSB
0
a
LSB
4-Byte Data
..
..
MSB
..
..
MSB
© by ASM GmbH