POSITAPE
®
Manuel de montage et de mise en service
Sortie CAN SAE J1939
Description
MCANJ1939
NAME Fields
Parameter Group
Numbers (PGN)
Specifications
© by ASM GmbH
Codeur linéaire selon le standard SAE J1939. Configuration des paramètres
par proprietary-A- Message (peer-to-peer connection). Transfert des don-
nées de process par proprietary-B-Message (broadcast).
CAN specification
Transceiver
Communication profile
Baud rate
Internal temination resistor
Address
Arbitrary address capable
Industry group
Vehicle system
Vehicle system instance
Function
Function instance
ECU instance
Manufacturer
Identity number
Configuration data
Process data
Excitation voltage
Excitation current
Resolution
Measuring rate
Stability (temperature)
Repeatability
Operating temperature
Protection
Dielectric strength
EMC Automation
www.asm-sensor.fr Tél.: +33 3 88 49 25 35
ISO 11898, Basic and Full CAN 2.0 B
24V-compliant, not isolated
SAE J1939
250 kBit/s
120 Ω user programmable
Default 247d, configurable
1
0
7Fh (127d)
0
FFh (255d)
0
0
145h (325d)
0nnn
PGN EFddh
PGN FFnnh
8 ... 36 V DC
20 mA typique pour 24 V DC,
40 mA typique pour 12 V DC,
80 mA max.
10 µm
1 kHz (asynchronous)
±50 x 10
/ °C f.s.
-6
1 LSB
-40 ... +85 °C
Reverse polarity, short circuit
1 kV (V AC, 50 Hz, 1 min.)
DIN EN 61326-1:2013
*) WB10, WB100M: -20 ... +85 °C
Yes
Global
Non specific
Non specific
Manufacturer ID
Serial number 21 bit
Proprietary-A
(PDU1 peer-to-peer)
dd Sensor Node ID
Proprietary-B
(PDU2 broadcast);
nn Group Extension
(PS) configurable
MAN-WB-F-16