INSTALLATION
Access
Panel
Screw
Installing a Floor Mount Unit to the Floor
9. Re-install the access panels on the bottom of each locker
column on the customer and operator sides using the
previously removed screws.
10. Plug the unit into a properly grounded electrical receptacle
of the correct voltage, size, and plug configuration. See
the SPECIFICATIONS section for details.

Installing Built-In Models

1. Cut the wall (if necessary) and build a rough opening in the
wall for the size of the unit being installed. Refer to "Rough
Opening Dimensions" in this section.
• Locate the unit in an area where the ambient air
temperature is constant and a minimum of 70°F (21°C).
Rough Opening Dimensions
Model
Width (A)
F2GB-3
61-3/16" to 61-11/16"
(1554‒1567 mm)
F2GB-22
44-3/8" to 44-7/8"
(1127‒1140 mm)
F2GB-32
61-3/16" to 61-11/16"
(1554‒1567 mm)
F2GB-42
78" to 78-1/2"
(1981‒1994 mm)
F2GB-52
94-13/16" to 95-5/16"
(2408‒2421 mm)
F2GB-23
44-3/8" to 44-7/8"
(1127‒1140 mm)
F2GB-33
61-3/16" to 61-11/16"
(1554‒1567 mm)
F2GB-43
78" to 78-1/2"
(1981‒1994 mm)
Wall Cutout Dimensions
Mounting
Locations
Floor
Plate
Height (B)
17-3/16" to 17-11/16"
(436‒449 mm)
32" to 32-1/2"
(812‒825 mm)
32" to 32-1/2"
(812‒825 mm)
32" to 32-1/2"
(812‒825 mm)
32" to 32-1/2"
(812‒825 mm)
46-13/16" to 47-5/16"
(1188‒1201 mm)
46-13/16" to 47-5/16"
(1188‒1201 mm)
46-13/16" to 47-5/16"
(1188‒1201 mm)
A
B
2. Remove the access panels on the bottom and top of
each locker column on the customer side by removing the
screws.
3. Lift the unit and carefully place it into the wall opening
cutout. This step requires two or more people, depending
on the unit.
• The unit is placed into the wall opening from the
customer side of the wall.
Top Wall Bracket
Bottom Wall Bracket
Installing a Built-In Unit into a Wall
4. Verify that the unit is level before securing to the wall. The
self-closing doors will not work properly if unit is not level.
• The unit must be within 0.5° of level. Use washers on
the wall fasteners to level unit, if necessary.
5. Secure the unit to the wall using the appropriate fasteners
through the wall brackets and into the wall.
• The unit must be installed with at least two fasteners
along the top wall brackets and at least two fasteners
along the bottom wall brackets.
Access
Panel
Screw
Installing a Built-In Unit
6. Re-install the access panels on the bottom and top of each
locker column on the customer side using the previously
removed screws.
7. Install trim work around unit and wall cutout and/or apply
NSF-approved sealant around the edge of the unit and the
wall cutout.
8. Plug the unit into a properly grounded electrical receptacle
of the correct voltage, size, and plug configuration. See the
SPECIFICATIONS section for details.
10
English
Bottom Wall Bracket
Form No. F2GM-0820