Safety regulations for FineCoat spraying

All local regulations in force must be observed.
In order to ensure safe operation of the FineCoat
systems the safety regulations listed below must be
followed.
1. Read the operating manual carefully and follow the
instructions given in order to avoid possible danger.
2. Only coating materials with a flash point of 21 °C
or over may be sprayed, without additional
heating.
3. Use of this unit is prohibited in workshops which
come under explosion prevention ordinances.
4. Never operate near sources of ignition, e.g., open
flames, cigarettes, cigars and pipes, sparks, red-
hot wires, hot surfaces, etc.
5. Warning! Risk of injury by injection!
Never point the spray gun at persons or animals
For breaks in work always secure the spray gun
against unintentional operation (see page 17,
fig. 11).
All manuals and user guides at all-guides.com
g
6. Always wear a protective mask when spraying.
7. For safety reasons, never use solvents based on
8. Caution: When operating the FineCoat system
9. Extraction systems should be installed on-site in
10. The work-pieces to be sprayed must be earthed.
11. When cleaning the unit with solvents, never spray
12. When transporting the system, it must be suitably
13. Always remove the mains plug from the socket
14. Work or repairs to the electrical fittings must be
13
In order to avoid occupational illnesses, always
follow the manufacturer's instructions for the
materials, solvents and cleaning agents used when
preparing and using such materials and when
cleaning the unit. Protective clothing, gloves and, if
necessary, skin protection cream should be used to
protect the skin.
1,1,1 trichloroethane or methylene chloride.
indoors or outdoors, make sure that no solvent
vapors are carried towards the turbo-blower and
that no solvent containing vapors can
accumulate in the near the turbo-blower.
Position the turbo-blower on the opposite side to
the object to be sprayed. Check the wind
direction when spraying outdoors. When working
indoors, a sufficient flow of air must be ensured
for extracting the solvent vapors.
A minimum distance of 3 m must be maintained
between the turbo-blower and the object being
sprayed.
accordance with local regulations.
into a container with only a small opening
(bunghole). Formation of a explosive gas/air mixture.
The container must be earthed.
secured for the particular means of transport.
before carrying out any work on electrical
components.
carried out by a specialist electrician. This is also
valid even if there are references to such work in the
operating manual. No liability will be accepted for
improper installation.