GB
INPUTS, OUTPUTS AND OPERATIONS
Inputs
N. 20 COM
N. 21 AP/CH
N. 24 STOP
N. 22 APED
N.23 COM
N. 25 FOTO
N. 26 STPA
Outputs
2CAN
N. 12 (-)
N. 13 (+)
SERR
N. 13 (+)
N. 14 (-)
AUX
N. 15 (-)
(Pilot lamp)
N. 13 (+)
Accessoires
N. 16 (+)
± 24V
N. 17 (-)
LAMP
N. 18 (-)
± 24V
N. 19 (+)
Operations
OBSTACLE WHEN CLOSING
(only config. 3, 4, 5 and 6)
OBSTACLE WHEN OPENING
(only config. 3, 4, 5 and 6)
RELEASE STROKE
ENGAGEMENT STROKE
DIP SWITCH
DSW1
dip 1
Release / engagement stroke
dip 2
dip 3
dip 4
STPA In (partial stop on opening)
dip 8
DSW2
dip 1
dip 2
PROGRAMMING
Description
Common for commands
Makes the leaf open/close. See operating modes.
Stops all manoeuvres and until active it disables all manoeuvres. NC contact.
Pedestrian opening if the gate is closed.
Makes the gate close if the gate is open or stopped.
Common for safety devices
Photocell, NC contact, if the gate is closing it reverses the movement and until engaged it pre-
vents the gate from closing.
Photocell on opening, stops all manoeuvres and until engaged it disables all manoeuvres. When
released: gate opens.
Description
Second channel output if dip 3 = OFF it activates on receipt of the radio control.
If dip 3 = ON connect the TX photocells for test .
Output for lock power supply
24Vdc output for remote signalling of gate status:
• ON when closing
• ON when opening
• Steady light: gate leaves NOT closed
24Vdc output. Photocells power supply.
Intermittent output for LED flashing light.
Description
If an obstacle is detected while the gate is closing: the gate immediately reverses its motion and
makes up to 3 attempts to close.
If the obstacle remains, the gate remains stationary and waits for a command.
If an obstacle is detected while the gate is opening: the gate immediately reverses its motion for
15 seconds and then stops.
The opening stroke is preceded by a short stroke in the opposite direction in order to remove
the load on the leaves and facilitate electric lock release.
The closing stroke is followed by a short stroke at full power in order to facilitate electric lock
engagement.
Function
Pre-flashing
2CAN Out
Photocell test
Function
Not Used
Initial thrust
ON
Enabled
Enabled
Power sup. TX Photocells (test)
Resistive Edge
Enabled
ON
-
Disabled
20/36
OFF
Disabled
Disabled
Second radio control channel
Photocell 2
Disabled
OFF
-
Enabled