WITHOUT SLOW-DOWN
•
Regulator trimmer TR4 (SLOSP – slow-down speed) to the maximum setting
•
Close the gate completely.
•
Press the P1 learning button for at least 3 seconds
•
The PROG-DL8 LED starts flashing
•
Do not release button P1; keep it pressed for another 3 seconds
•
The PROG-DL8 starts to flash at a higher frequency
•
Do not release button P1; keep it pressed for another 3 seconds
•
The PROG-DL8 starts to flash at a higher frequency
•
Press START: The first leaf begins to open at standard speed
•
Press START, button P3 (AP/CH - open/close):
•
The first leaf begins to open at standard speed
Without LS card: When the leaf has opened completely, press START
With LS card:
Wait until the leaf opens completely
•
The first leaf begins to close at standard speed
Without LS card When the leaf has closed completely, press START
With LS card:
Wait until the leaf closes completely
-
Wait until the PROG-DL8 LED turns off.
-
Learning finished.
OPERATING MODES
Select an operating mode by means of DSW1 dip switches 5, 6 and 7 referring to the table below (after each mode change it is necessary
to jumper the JR1 RESET contacts for a few seconds so that the change can take effect):
dip5
dip6
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
(*) The courtesy function enables the gate to be closed 5 seconds after the photocells have received a pulse, regardless of the timing of
the pause setting.
CONDOMINIUM AUTOMATIC:
Pressing START when the gate is closed makes it open. Pressing START while the gate is opening has no effect. Once open, the gate re-
mains paused for the set pause time. Pressing START during the pause restarts the time counter from zero. Pressing START while the gate
is closing makes it open again.
SUPER AUTOMATIC:
Pressing START when the gate is closed makes it open. Pressing START while the gate is opening stops the gate; pressing START a se-
cond time makes it close again. Once open, the gate remains paused for the set pause time. Pressing START during the pause closes the
gate. Pressing START while the gate is closing makes it open again.
AUTOMATIC:
Pressing START when the gate is closed makes it open. Pressing START when the gate is opening has no effect. Once open, the gate re-
mains paused for the set pause time. Pressing START during the pause closes the gate. Pressing START while the gate is closing makes
it open again.
SEMI AUTOMATIC:
Pressing START when the gate is closed makes it open. Pressing START while the gate is opening stops the gate; pressing START a se-
cond time makes it close again. The gate remains open until START is pressed, which makes it close. Pressing START while the gate is
closing makes it open again.
STEP BY STEP:
Pressing START when the gate is closed makes it open. Pressing START while the gate is opening stops the gate; pressing START a se-
cond time makes it close again. The gate remains open until START is pressed, which makes it close. When the gate is closing, pressing
START stops the gate and pressing START a second time makes it open again.
PROGRAMMING
DWS1 – operating mode
dip7
Mode
OFF
Condominium automatic
ON
Condominium automatic + courtesy (*)
OFF
Super automatic
ON
Super automatic + courtesy (*)
OFF
Automatic
ON
Automatic + comfort (*)
OFF
Semi automatic
ON
Step by step
19/36