General Features; Mechanical Installation - Elvox ECA8 Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GB
The EC80 equipment has been designed to control the operation of 230 V AC electromechanical actuators for the automation of swing gates.
Any other use is to be considered improper and therefore hazardous.
It is prohibited to use the product for an improper purpose or for any purpose other than its intended use.
It is prohibited to tamper with or modify the product.
The manufacturer assumes no liability for failure to comply with these requirements.
Technical data
Before installing the product, check that the temperature limits indicated are suitable for the installation environment.
SINGLE-PHASE SUPPLY VOLTAGE
FREQUENCY
MOTOR SUPPLY VOLTAGE
MOTOR MAXIMUM POWER
VOLTAGE FOR EXTERNAL DEVICES
MAXIMUM ABSORBED POWER EXT. DEV.
EQUIPMENT AND ACCESSORIES PROTECTION
MOTOR PROTECTION
TEMPERATURE RANGE
PROTECTION RATING
ECA8 OVERALL DIMENSIONS (mm)

MECHANICAL INSTALLATION

For correct installation, fix the box in a secure place where it is protected from the weather. To mount the box on the wall remove the 4
plastic screws, open the cover and fasten the box to the wall with 4 plugs.
NOTE: in order to determine the opening and closing points of the gate leaves, if the limit switch card (optional) is not used, mechanical
stops must be fitted at the desired opening and closing positions (Art. ZD27).

GENERAL FEATURES

230 V AC +6% -10 %
50 Hz
230 V AC +6% -10 %
300 W
24 V DC +15% -10%
20 W
T1 A time-delay fuse (F1)
5 A fuse (F2)
- 20 to +70 °C inside enclosure
IP55
14/36

Publicité

Table des Matières
loading