Disposal of the Unit

• Do not dispose of the unit with general waste.
Do not include the monitor with household waste.
• The fluorescent tube includes mercury. Dispose of the
monitor in accordance with the regulations of your
local sanitation authority.
Recommendation to Use more than
One Unit
As problems can occasionally occur for the monitor,
when the monitor is used for safety control of personnel,
assets or stable picture, or for emergencies, we strongly
recommend you use more than one unit or prepare a
spare unit.

On Repacking

Do not throw away the carton and packing materials.
They make an ideal container which to transport the
unit.
If you have any questions about this unit, contact your
authorized Sony dealer.

On Fan Error

The fan for cooling the unit is built in. When the fan
stops and the RETURN button on the front panel blinks
for fan error indication, turn off the power and contact an
authorized Sony dealer.

On Moisture Condensation

If the unit is brought directly from a cold place to a warm
place, or the unit is warm and the ambient temperature
cools suddenly (by air-conditioning, for example),
moisture may condense on the surface or inside of the
unit, or create a mist residue inside the protection plate.
This is called moisture condensation, and is not a
malfunction of the product itself, although it may cause
damage to the unit.
Leave the unit in a condensation free area.
If moisture condensation has occurred, turn off the unit
and do not use it until moisture condensation has
evaporated.
48

Features

Features
Compliance with medical safety
standards in U.S.A., Canada and Europe
IEC 60601-1 and product safety standards in the U.S.A.,
Canada and Europe have been obtained for this monitor.
The monitor is designed for use in the medical treatment
field, with the sheet switch, screen protect panel, etc.
Picture
Fully digital 10-bit signal processing circuit
As well as digital signals, all signals including analog
signals are converted into digital signals. All signals are
processed using a fully digital 10-bit processing circuit
so that an image is produced in smooth gradation
without any deterioration of quality.
Two color system available
The monitor can display NTSC and PAL signals by
connecting this unit.
Auto chroma/phase function
The chroma and phase of the decoder are automatically
adjusted with the auto chroma phase function.
High image-quality/high-resolution Full HD
LCD panel with 10-bit driver
A Full HD high-resolution/high-gradient (1920 × 1080
dots) panel and high brightness/ultra-wide field of view
technology enables you to use the monitor under various
lighting conditions and in numerous ways (installing on
wall, using several monitors to view an image, and so
on.).
Because a color filter with wide-color reproduction and
LCD materials with high response speed are used, the
motion picture of the video signal is displayed clearer.
This monitor also performs sampling of signals at high
frequencies and provides a high resolution of 700 TV
scanning lines or more during the RGB or component
signal (480/60I, 575/50I) input.
Input
Accepts analog RGB input signals
Adopting the scan converter allows this monitor to
detect VGA, SVGA, XGA and SXGA analog RGB
signals input to the HD15 input connector.
*1