k Optional input slot
An optional input adaptor can be installed according to
your system configuration (see page 56).
The upper slot is A and the lower slot is B.
Press the A-1, A-2, B-1 or B-2 button to select the
signal.
The BKM-243HS (HD/D1-SDI input adaptor) is
preattached in slot A in this unit.
l PARALLEL REMOTE connector (modular
connector, 8-pin)
Forms a parallel switch and controls the monitor
externally.
When the unit is shipped from the factory, a connector
cover is attached to this connector. Remove it before
using the connector.
For removing the connector cover, see page 56.
For details on the pin assignment and factory setting
function assigned to each pin, see page 72.
CAUTION
For safety, do not connect the connector for peripheral
device wiring that might have excessive voltage to this
port. Follow the instructions for this port.
m SERIAL REMOTE connector (RJ-45)
Connect to the network by using a 10BASE-T/
100BASE-TX LAN cable (shielded type, optional).
When the unit is shipped from the factory, a connector
cover is attached to this connector. Remove it before
using the connector.
For removing the connector cover, see page 56.
For details on this connector, refer to the Interface
Manual for Programmers (saved in the supplied CD-
ROM, Japanese and English only.)
CAUTION
• When an optional LAN cable is connected, use a
shield type cable to prevent miss-operation due to
noises.
• For safety, do not connect the connector for peripheral
device wiring that might have excessive voltage to this
port. Follow the instructions for this port.
• The connection speed may be affected by the network
system. This unit does not guarantee the
communication speed or quality of 10BASE-T/
100BASE-TX.
n SERIAL REMOTE RS-232C connector (D-sub
9-pin, female)
Connect to the RS-232C control connector on external
equipment connected to the monitor. The monitor can
be operated according to control commands sent from
external equipment connected to it.
For details on the pin assignment and factory setting
function assigned to each pin, see page 72.
54
Location and Function of Parts and Controls
For details, refer to the Interface Manual for
Programmers (saved in the supplied CD-ROM,
Japanese and English only.)
o DVI-D input connector (DVI-D)
Inputs DVI Rev.1.0 applicable digital RGB signal.
To view the signals of the SXGA and higher resolution
when the DVI input is selected, use the cable within 3 m
1
(118
inches) in length.
/8
p HD15 input connector (D-sub 15-pin, female)
Inputs an analog RGB video signal (0.7 Vp-p, positive
polarity) and sync signal.
The Plug & Play function corresponds to DDC2B.