3
Technical data
Information / pump type
Weight
Power P1 / P2
Speed
Operating voltage
Rated current
Max. pumping capacity
Max. pumping height
Max. temperature
Pumping medium
Protection rating
Protection class
Operating mode
Motor protection
Recommended fuse
Residual current device (RCD)
Pumping capacity and height of the pumps
Tank
Data
Weight
Inlet [DN]
Pressure connection [DN]
Cable conduit
Ventilation
Height
Outside diameter
Cover plate / version
Pumping volume GTF 600
GTF 1250
Floater switching level
GTF 600 / GTF
1250 pump
016-232_01
GTF 600
650W / 400 W
2750 rpm
230 V; 50 Hz
IP68 (3m)
integrated
Fig. 1: Pumping capacity diagram
Values
16 kg
100 / 150
must be drilled on-site
50 (d=63 mm) for PVC
must be drilled on-site
must be drilled on-site
must be drilled on-site
830 mm
600 mm
walkonable up to 300 kg
20 l
25 l
ON
OFF
260mm
160mm
Installation and operating instructions
6 kg
2.9 A
12 m³/h
8 m
35°C
I
S1
C16 A
30 mA
GTF 1250
10 kg
1.3 kW / 0.8 kW
2700 rpm
230 V; 50 Hz
5.4 A
20 m³/h
11 m
35°C
IP68 (3m)
I
S3 (50%)
integrated
C16 A
30 mA
21 / 84