2. Installation instructions

2.1 Structure of the device

A D M
1 Temperature selection switch
2 Signal lamp for operating mode display
3 Lights for the heat content display
4 „SERVICE ANODE" signal lamp
5 Operating panel
6 Hot water outlet nozzle G ½
7 Cold water inlet nozzle G ½
8 Inflow
9 Cable duct PG 21 for electrical
connection
10 Drain valve with hose connection G ¾
11 Pressure switch for signal anode
12 Reset button for safety temperature
limiter (actuation from the front)
13 Regulator-limiter combination
14 Seal
15 Cover caps
16 Signal anode
– SH 30 S (M 8):
Replace with heating element fitting
– SH 50 - 150 S (G 3/4):
Replace without heating element fitting
17 Heating element
18 Outflow pipe
19 Suspension bar top*
20 Suspension bar bottom*
(on SH 120 S and SH 150 S)
21 Thermostat
22 Safety temperature limiter
23 Pressure switch for signal anode
24 Heat content display
25 Plug distributor for N-lead
26 Terminal for power switchover
* For screws dia. 12 mm provided by
customer

2.2 Fittings

• Unvented (pressurized) mode of opera-
tion: Safety groups kV 30 or kV 40
• Vented (pressureless) mode of operation:
G
Fittings without pressure
.

2.4 Technical data

(the data on the unit rating plate are applicable)
Type
SH 30 S
l 30
Capacity
Mixed water quantity l 59
40 °C (15 °C / 65 °C)
Weight empty
kg 23,1
Connectable to power
sources
Permissible operating pressure
Protection class EN 60529
Test marking

Water connection

Flow rate
Dimensions a
mm
420
D
b
mm
410
h
mm
750
i
mm
k
mm
700
l
mm
70
Table 1
for the qualified installer
2.3 Regulations and
provisions
• The installation (water and electrical
installation) and first start-up, as well as the
maintenance of this unit may only be
carried out by an approved specialist
installer in accordance with these
Instructions.
• Perfect function and operational safety are
only guaranteed with original accessories
and spare parts intended for the unit.
The installation should be carried out in
accordance with the relevant water
(WRAS) and electrical (IEE) guidelines and
regulations.
Installation should be carried out in
accordance with the relevant water and
electricity supply companys regulations.
The following are also to be respected:
• The unit rating plate
• Technical data
• Water installation
Pipe material:
– Cold water pipe
Copper pipe
Steel pipe
Plastic pipe systems with the instantanous
water heater the operating temperature
can be adjusted upto max. 82 °C. The
maximum temperature can be limited to
65 °C. In case of failures temperatures can
rise up to 95 °C (max. 0.6 MPa).
The assigned plastic pipe system must be
appropriate for these conditions.

• Electrical installation

– Electrical connection only with fixed-laid
leads in association with removable
cable bushings.
F
.
– The unit must be capable of all-pole
disconnection from the mains, for
example by fuses, with an isolating
distance of at least 3 mm.
SH 50 S
SH 80 S
SH 100 S
50
80
100
97
159
198
28,0
38,0
40,8
1 - 4 kW
1/N/PE ~ 230 V
3 - 4 kW
2/N/PE ~ 400 V
6 kW
3/N/PE ~ 400 V
0.6 MPa (6 bar)
IP 25 D
See unit rating plate
G ½ (external thread)
max. 18 l/min
510
510
510
510
510
510
720
1030
1030
600
900
900
140
150
150

2.5 Installation location

• In an area not subject to the risk of
freezing.
• Install close to the water tap.

2.6 Unit installation

• Fit the suspension bracket.
Select the securing material to suit the
strength of the wall. With SH 120 S and
SH 150 S, two suspension brackets are
required.
Any unevenness in the wall is to be
compensated for by the spacer elements
provided (a. approx. 5 mm thick).
• Install in a vertical position; see
• Push the cover caps onto the suspension
bracket
2.7 Water connection
• Unvented (pressurized) for the
supply of several draw-off points.
– Install the type-tested safety groups
KV 30, Order No. 00 08 26, up to
0.48 MPa water pipe pressure
– Hot water pipe
KV 40, Order No. 00 08 28, up to 1 MPa
Copper pipe
water pipe pressure
Steel or copper pipe
a Safety valve
b Backflow preventer
c Test valve
d Throughflow isolating valve (choke)
e Pressure reducer (with KV 40)
f Test nozzle for pressure gauge
g Thermostat fitting TA 260 Order No.
– Establish dimensions for the outflow pipe
for a fully-opened safety valve. The drain
aperture of the safety valve must remain
open to the atmosphere.
– The drain for the safety group is to be
installed with a constant downwards
inclination.
– The information provided in the
Installation Instructions for the safety
group are to be respected.
– Set a maximum flow rate of 18 l/min at
SH 120 S
SH 150 S
the choke of the safety group.
120
150
• Vented (pressureless) for the supply
235
292
of one single draw-off point
The units are suitable for vented
45,5
53,3
(pressureless) operation mode.
– With this installation the Stiebel Eltron
fittings for vented wall-mounted water
heaters
– Before connecting the fitting the water
pipe must be thoroughly flushed through.
– For use, installation, first start-up, and
maintenance, the same instructions apply
510
510
as for the operation of unvented
510
510
(pressurized) water heaters.
1190
1425
300
300
Instructions for „Signal anode in
unpressurized operating mode"
900
1100
the page 14.
310
345
E
D
E
(b).
00 34 66 (order separately), also
possible in conjunction with KV 40.
Do not block off the drain and
fittings pivot arm.
G
are to be used.
.
F
13