Ports And Connections; Conic Sealing Pads - Pratissoli SM Série Manuel D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30
Viscosity / Room Temperature diagram
mm
/s = cSt
2
The used oil must be placed in a suitable container and disposed of in special centres.
It absolutely should not be discarded into the environment.
8

PORTS AND CONNECTIONS

The KE series pumps (see Fig. 4) are equipped with:
 2 "IN" inlet ports 1"1/2 Gas.
Line connection to any of the two ports is indifferent for
proper pump functioning. The unused ports must be
hermetically closed.
 2 "OUT" outlet ports Ø13 mm.
 2 service ports 1/2" Gas; they can be used for the pressure
gauge and the safety valve.
 1 drain port "DRAIN " supplied with an adjustable 90° rapid
fitting for extØ 12 mm polyamide pipes. It is used to recover
the fluid drained from the packing cooling circuit, and must
be connected to the outlet port being careful to avoid
counter-pressure.
Ambient temp. (°C)
8.1

Conic sealing pads

The VK pumps are equipped with 4 conic steel pads to be
used in correspondence with the pump's delivery ports (see
Fig. 5) or in the optional fitting flanges. Their function is to
guarantee the sealing of the connection. The seat of the
pump's delivery port is already machined in order to hold the
conic pad; if necessary, the connections for the delivery fitting
or the closing plug must be specially machined as indicated in
Fig. 5/a.
At each disassembly, the conic pads must be
replaced.
PAD
Fig. 4
21
PLUG
PUMP HEAD
Fig. 5